ID |
Date |
Author |
Project |
Measurement Type |
Object ID |
Subject |
|
1
|
Fri Apr 18 17:23:26 2008 |
Markus Friedl | SPS Testbeam June08 | hybrid | hybrid 01 | Noise of hybrid 01, sensor fully bonded, no HV |
HV bias not yet glued to backplane |
Attachment 1: hybrid01_sen_nohv_pednoise_apv0.png
|
|
Attachment 2: hybrid01_sen_nohv_pednoise_apv1.png
|
|
|
2
|
Tue Apr 22 19:34:09 2008 |
Markus Friedl | SPS Testbeam June08 | module | hybrid 01 | Properties of hybrid 01, sensor fully bonded, HV=100V |
HV bias glued to backplane, HV=100V |
Attachment 1: hybrid01_sen_hv100V_cal_apv0.png
|
|
Attachment 2: hybrid01_sen_hv100V_cal_apv1.png
|
|
Attachment 3: hybrid01_sen_hv100V_pednoise_apv0.png
|
|
Attachment 4: hybrid01_sen_hv100V_pednoise_apv1.png
|
|
Attachment 5: hybrid01_sen_hv100V_cmnoise_apv0.png
|
|
Attachment 6: hybrid01_sen_hv100V_cmnoise_apv1.png
|
|
|
3
|
Wed Apr 23 13:05:05 2008 |
Christian Irmler | SPS Testbeam June08 | source | hybrid 01 | time correlation between TDC and sensor measurement -> 3.1 ns RMS |
|
Attachment 1: vie_run001_tpeak_vs_TDC.gif
|
|
|
4
|
Wed Apr 23 13:37:18 2008 |
Markus Friedl | SPS Testbeam June08 | source | hybrid 01 | analysis results of source test |
Ignore the "KEK November 2007" title - that's a legacy and is already changed :-)
As of now, there is no distinction in 16 separate zones. However, the gaps between the the zones are clearly visible in the Hit Profile, as the edge strips on both sides have a larger sensitive area and thus collect more hits than other strips; hence the spikes in the (otherwise pretty gaussian) beam profile. There is a single strip with no entries in the center - that's the one that suffered from the bias bond repair action.
SNR=21 (peak mode) is pretty healthy and fits to similar detectors operated with APV25.
All data was taken in multi-peak mode with subsequent hit fitting to obtain amplitude and timing (see separate posting for timing precision).
The verbose output of the analysis is pasted below.
Analysis of vie_run001
Peak Mode, 3 x 200 initevents (first 10 skipped) + 99400 events
Number hybrids: 1 number zones: 2 number sensors: 1
Using calibration file vie_cal001
No pedestal correction file
Seed/Neighbor/Cluster/Noisy Strips Cuts [RMS noise]: 5.0/3.0/5.0
Min. hitlength: 3
Comments:
SILC module 01
HV=100V, 40MHz, Tp=50ns, 30ns
Sr90 1mCi , black cloth cover
Analysis date: 23.04.2008 13:25:09
Analysis settings:
runname: vie_run001_cluster
clock: 40.00 MHz
datafilepath: data/
outputpath: output/
subevents: 6
fitmode: 2 (cal. fit)
options: h
Results:
ModuleName ZoneType Ch OKCh OK% Entries MClW MPSignal Noise MPSNR HpSE Occup
p_side JP single sensor 256 256 100.0 90385 2.53 21546.1 729.4 20.68 0.53 1.81 |
Attachment 1: vie_run001_cluster_sig_0.gif
|
|
Attachment 2: vie_run001_cluster_noi_0.gif
|
|
Attachment 3: vie_run001_cluster_hit_0.gif
|
|
Attachment 4: vie_run001_cluster_clw_0.gif
|
|
|
6
|
Wed May 7 15:24:49 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 10/02 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100V) = 19.1 nA
Ibias (200V) = 23.7 nA |
Attachment 1: modul1002_1row_cal_apv0.png
|
|
Attachment 2: modul1002_1row_cal_apv1.png
|
|
Attachment 3: modul1002_1row_cmnoise_apv0.png
|
|
Attachment 4: modul1002_1row_cmnoise_apv1.png
|
|
Attachment 5: modul1002_1row_pednoise_apv0.png
|
|
Attachment 6: modul1002_1row_pednoise_apv1.png
|
|
Attachment 7: modul1002_final_cal_apv0.png
|
|
Attachment 8: modul1002_final_cal_apv1.png
|
|
Attachment 9: modul1002_final_cmnoise_apv0.png
|
|
Attachment 10: modul1002_final_cmnoise_apv1.png
|
|
Attachment 11: modul1002_final_pednoise_apv0.png
|
|
Attachment 12: modul1002_final_pednoise_apv1.png
|
|
|
9
|
Wed May 7 15:26:24 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 20/09 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 25.1 nA
Ibias (200 V) = 31.4 nA |
Attachment 1: modul2009_1row_cal_apv0.png
|
|
Attachment 2: modul2009_1row_cal_apv1.png
|
|
Attachment 3: modul2009_1row_cmnoise_apv0.png
|
|
Attachment 4: modul2009_1row_cmnoise_apv1.png
|
|
Attachment 5: modul2009_1row_pednoise_apv0.png
|
|
Attachment 6: modul2009_1row_pednoise_apv1.png
|
|
Attachment 7: modul2009_final_cal_apv0.png
|
|
Attachment 8: modul2009_final_cal_apv1.png
|
|
Attachment 9: modul2009_final_cmnoise_apv0.png
|
|
Attachment 10: modul2009_final_cmnoise_apv1.png
|
|
Attachment 11: modul2009_final_pednoise_apv0.png
|
|
Attachment 12: modul2009_final_pednoise_apv1.png
|
|
|
8
|
Wed May 7 15:40:07 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 07/07 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 20.2 nA
Ibias (200 V) = 21.9 nA |
Attachment 1: modul0707_1row_cal_apv0.png
|
|
Attachment 2: modul0707_1row_cal_apv1.png
|
|
Attachment 3: modul0707_1row_cmnoise_apv0.png
|
|
Attachment 4: modul0707_1row_cmnoise_apv1.png
|
|
Attachment 5: modul0707_1row_pednoise_apv0.png
|
|
Attachment 6: modul0707_1row_pednoise_apv1.png
|
|
Attachment 7: modul0707_final_cal_apv0.png
|
|
Attachment 8: modul0707_final_cal_apv1.png
|
|
Attachment 9: modul0707_final_cmnoise_apv0.png
|
|
Attachment 10: modul0707_final_cmnoise_apv1.png
|
|
Attachment 11: modul0707_final_pednoise_apv0.png
|
|
Attachment 12: modul0707_final_pednoise_apv1.png
|
|
|
7
|
Wed May 7 16:12:58 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 12/08 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 22.2 nA
Ibias (200 V) = 26.5 nA |
Attachment 1: modul1208_1row_cal_apv0.png
|
|
Attachment 2: modul0707_1row_cal_apv1.png
|
|
Attachment 3: modul0707_1row_cmnoise_apv0.png
|
|
Attachment 4: modul0707_1row_cmnoise_apv1.png
|
|
Attachment 5: modul0707_1row_pednoise_apv0.png
|
|
Attachment 6: modul0707_1row_pednoise_apv1.png
|
|
Attachment 7: modul0707_final_cal_apv0.png
|
|
Attachment 8: modul0707_final_cal_apv1.png
|
|
Attachment 9: modul0707_final_cmnoise_apv0.png
|
|
Attachment 10: modul0707_final_cmnoise_apv1.png
|
|
Attachment 11: modul0707_final_pednoise_apv0.png
|
|
Attachment 12: modul0707_final_pednoise_apv1.png
|
|
|
10
|
Wed May 7 19:05:08 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 04/04 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 27.8 nA
Ibias (200 V) = 32.7 nA |
Attachment 1: modul0404_1row_cal_apv0.png
|
|
Attachment 2: modul0404_1row_cal_apv1.png
|
|
Attachment 3: modul0404_1row_cmnoise_apv0.png
|
|
Attachment 4: modul0404_1row_cmnoise_apv1.png
|
|
Attachment 5: modul0404_1row_pednoise_apv0.png
|
|
Attachment 6: modul0404_1row_pednoise_apv1.png
|
|
Attachment 7: modul0404_final_cal_apv0.png
|
|
Attachment 8: modul0404_final_cal_apv1.png
|
|
Attachment 9: modul0404_final_cmnoise_apv0.png
|
|
Attachment 10: modul0404_final_cmnoise_apv1.png
|
|
Attachment 11: modul0404_final_pednoise_apv0.png
|
|
Attachment 12: modul0404_final_pednoise_apv1.png
|
|
|
11
|
Fri May 9 09:56:15 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 06/03 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 26.5 nA
Ibias (200 V) = 37.8 nA |
Attachment 1: modul0603_1row_cal_apv0.png
|
|
Attachment 2: modul0603_1row_cal_apv1.png
|
|
Attachment 3: modul0603_1row_cmnoise_apv0.png
|
|
Attachment 4: modul0603_1row_cmnoise_apv1.png
|
|
Attachment 5: modul0603_1row_pednoise_apv0.png
|
|
Attachment 6: modul0603_1row_pednoise_apv1.png
|
|
Attachment 7: modul0603_final_cal_apv0.png
|
|
Attachment 8: modul0603_final_cal_apv1.png
|
|
Attachment 9: modul0603_final_cmnoise_apv0.png
|
|
Attachment 10: modul0603_final_cmnoise_apv1.png
|
|
Attachment 11: modul0603_final_pednoise_apv0.png
|
|
Attachment 12: modul0603_final_pednoise_apv1.png
|
|
|
12
|
Fri May 9 10:00:34 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 03/10 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 18.9 nA
Ibias (200 V) = 25.5 nA |
Attachment 1: modul0310_1row_cal_apv0.png
|
|
Attachment 2: modul0310_1row_cal_apv1.png
|
|
Attachment 3: modul0310_1row_cmnoise_apv0.png
|
|
Attachment 4: modul0310_1row_cmnoise_apv1.png
|
|
Attachment 5: modul0310_1row_pednoise_apv0.png
|
|
Attachment 6: modul0310_1row_pednoise_apv1.png
|
|
Attachment 7: modul0310_final_cal_apv0.png
|
|
Attachment 8: modul0310_final_cal_apv1.png
|
|
Attachment 9: modul0310_final_cmnoise_apv0.png
|
|
Attachment 10: modul0310_final_cmnoise_apv1.png
|
|
Attachment 11: modul0310_final_pednoise_apv0.png
|
|
Attachment 12: modul0310_final_pednoise_apv1.png
|
|
|
13
|
Fri May 9 10:04:26 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 05/05 | properties (noise, intcal), APVs bonded to the sensor |
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 18.0 nA
Ibias (200 V) = 23.6 nA |
Attachment 1: modul0505_1row_cal_apv0.png
|
|
Attachment 2: modul0505_1row_cal_apv1.png
|
|
Attachment 3: modul0505_1row_cmnoise_apv0.png
|
|
Attachment 4: modul0505_1row_cmnoise_apv1.png
|
|
Attachment 5: modul0505_1row_pednoise_apv0.png
|
|
Attachment 6: modul0505_1row_pednoise_apv1.png
|
|
Attachment 7: modul0505_final_cal_apv0.png
|
|
Attachment 8: modul0505_final_cal_apv1.png
|
|
Attachment 9: modul0505_final_cmnoise_apv0.png
|
|
Attachment 10: modul0505_final_cmnoise_apv1.png
|
|
Attachment 11: modul0505_final_pednoise_apv0.png
|
|
Attachment 12: modul0505_final_pednoise_apv1.png
|
|
|
18
|
Wed May 7 14:36:29 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 1 of 6 room temperature measurements using Sr90 Source (multi6) |
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left)
HV Turned to +40,-40V with currents. +1.2 and -1.2 µA
N+1.25V current: 0.22A
N+2.5 V current: 0.56A
P+1.25V current: 0.26A
P+2.50V current: 0.70A
Events: 200000 |
Attachment 1: run01_all_hits_apv0.png
|
|
Attachment 2: run01_all_hits_apv1.png
|
|
Attachment 3: run01_all_hits_apv2.png
|
|
Attachment 4: run01_all_hits_apv3.png
|
|
Attachment 5: run01_all_hits_apv4.png
|
|
Attachment 6: run01_all_hits_apv5.png
|
|
Attachment 7: run01_all_hits_apv6.png
|
|
Attachment 8: run01_all_hits_apv7.png
|
|
Attachment 9: run01_all_hits_apv8.png
|
|
Attachment 10: run01_all_hits_apv9.png
|
|
|
19
|
Wed May 7 15:04:32 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 2 of 6 room temperature measurements using Sr90 Source (multi6) |
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center)
HV Turned to +40,-40V with currents. +1.23 and -1.25 µA
N+1.25V current: 0.22A
N+2.50V current: 0.56A
P+1.25V current: 0.26A
P+2.50V current: 0.71A
Events: 200000 |
Attachment 1: run02_all_hits_apv0.png
|
|
Attachment 2: run02_all_hits_apv1.png
|
|
Attachment 3: run02_all_hits_apv2.png
|
|
Attachment 4: run02_all_hits_apv3.png
|
|
Attachment 5: run02_all_hits_apv4.png
|
|
Attachment 6: run02_all_hits_apv5.png
|
|
Attachment 7: run02_all_hits_apv6.png
|
|
Attachment 8: run02_all_hits_apv7.png
|
|
Attachment 9: run02_all_hits_apv8.png
|
|
Attachment 10: run02_all_hits_apv9.png
|
|
|
20
|
Wed May 7 15:53:38 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 3 of 6 room temperature measurements using Sr90 Source (multi6) |
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right)
HV Turned to +40,-40V with currents. +1.25 and -1.26 µA
N+1.25V current: 0.22A
N+2.50V current: 0.56A
P+1.25V current: 0.26A
P+2.50V current: 0.71A
Events: 200000 |
Attachment 1: run03_all_hits_apv0.png
|
|
Attachment 2: run03_all_hits_apv1.png
|
|
Attachment 3: run03_all_hits_apv2.png
|
|
Attachment 4: run03_all_hits_apv3.png
|
|
Attachment 5: run03_all_hits_apv4.png
|
|
Attachment 6: run03_all_hits_apv5.png
|
|
Attachment 7: run03_all_hits_apv6.png
|
|
Attachment 8: run03_all_hits_apv7.png
|
|
Attachment 9: run03_all_hits_apv8.png
|
|
Attachment 10: run03_all_hits_apv9.png
|
|
|
21
|
Wed May 7 16:43:37 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 4 of 6 room temperature measurements using Sr90 Source (multi6) |
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left)
HV Turned to +40,-40V with currents. +1.25 and -1.26 µA
N+1.25V current: 0.22A
N+2.50V current: 0.57A
P+1.25V current: 0.26A
P+2.50V current: 0.72A
Events: 200000 |
Attachment 1: run04_all_hits_apv0.png
|
|
Attachment 2: run04_all_hits_apv1.png
|
|
Attachment 3: run04_all_hits_apv2.png
|
|
Attachment 4: run04_all_hits_apv3.png
|
|
Attachment 5: run04_all_hits_apv4.png
|
|
Attachment 6: run04_all_hits_apv5.png
|
|
Attachment 7: run04_all_hits_apv6.png
|
|
Attachment 8: run04_all_hits_apv7.png
|
|
Attachment 9: run04_all_hits_apv8.png
|
|
Attachment 10: run04_all_hits_apv9.png
|
|
|
22
|
Wed May 7 17:33:21 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 5 of 6 room temperature measurements using Sr90 Source (multi6) |
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center)
HV Turned to +40,-40V with currents. +1.22 and -1.24 µA
N+1.25V current: 0.22A
N+2.50V current: 0.56A
P+1.25V current: 0.26A
P+2.50V current: 0.70A
Events: 200000 |
Attachment 1: run05_all_hits_apv0.png
|
|
Attachment 2: run05_all_hits_apv1.png
|
|
Attachment 3: run05_all_hits_apv2.png
|
|
Attachment 4: run05_all_hits_apv3.png
|
|
Attachment 5: run05_all_hits_apv4.png
|
|
Attachment 6: run05_all_hits_apv5.png
|
|
Attachment 7: run05_all_hits_apv6.png
|
|
Attachment 8: run05_all_hits_apv7.png
|
|
Attachment 9: run05_all_hits_apv8.png
|
|
Attachment 10: run05_all_hits_apv9.png
|
|
|
23
|
Wed May 7 18:20:36 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 6 of 6 room temperature measurements using Sr90 Source (multi6) |
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right)
HV Turned to +40,-40V with currents. +1.2 and -1.22 µA
N+1.25V current: 0.22A
N+2.50V current: 0.56A
P+1.25V current: 0.26A
P+2.50V current: 0.70A
Events: 200000 |
Attachment 1: run06_all_hits_apv0.png
|
|
Attachment 2: run06_all_hits_apv1.png
|
|
Attachment 3: run06_all_hits_apv2.png
|
|
Attachment 4: run06_all_hits_apv3.png
|
|
Attachment 5: run06_all_hits_apv4.png
|
|
Attachment 6: run06_all_hits_apv5.png
|
|
Attachment 7: run06_all_hits_apv6.png
|
|
Attachment 8: run06_all_hits_apv7.png
|
|
Attachment 9: run06_all_hits_apv8.png
|
|
Attachment 10: run06_all_hits_apv9.png
|
|
|
26
|
Thu May 8 16:51:03 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 1 of 6 room temperature measurements using Sr90 Source (single) |
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left)
HV Turned to +40,-40V with currents. +1.0 and -1.0 µA
N+1.25V current: 0.22A
N+2.50V current: 0.57A
P+1.25V current: 0.26A
P+2.50V current: 0.72A
Events: 200000 |
Attachment 1: run07_all_hits_apv0.png
|
|
Attachment 2: run07_all_hits_apv1.png
|
|
Attachment 3: run07_all_hits_apv2.png
|
|
Attachment 4: run07_all_hits_apv3.png
|
|
Attachment 5: run07_all_hits_apv4.png
|
|
Attachment 6: run07_all_hits_apv5.png
|
|
Attachment 7: run07_all_hits_apv6.png
|
|
Attachment 8: run07_all_hits_apv7.png
|
|
Attachment 9: run07_all_hits_apv8.png
|
|
Attachment 10: run07_all_hits_apv9.png
|
|
|
27
|
Thu May 8 16:51:57 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 2 of 6 room temperature measurements using Sr90 Source (single) |
Failed with Error: "***ERROR*** Init NECO failed, Return code: -32761"
Restarted and it works again
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center)
HV Turned to +40,-40V with currents. +0.97 and -1.0 µA
N+1.25V current: 0.22A
N+2.50V current: 0.57A
P+1.25V current: 0.26A
P+2.50V current: 0.73A
Events: 200000 |