9
|
Wed May 7 15:26:24 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 20/09 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 25.1 nA
Ibias (200 V) = 31.4 nA |
12x |
|
7
|
Wed May 7 16:12:58 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 12/08 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 22.2 nA
Ibias (200 V) = 26.5 nA |
12x |
|
6
|
Wed May 7 15:24:49 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 10/02 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100V) = 19.1 nA
Ibias (200V) = 23.7 nA |
12x |
|
8
|
Wed May 7 15:40:07 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 07/07 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 20.2 nA
Ibias (200 V) = 21.9 nA |
12x |
|
11
|
Fri May 9 09:56:15 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 06/03 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 26.5 nA
Ibias (200 V) = 37.8 nA |
12x |
|
13
|
Fri May 9 10:04:26 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 05/05 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 18.0 nA
Ibias (200 V) = 23.6 nA |
12x |
|
10
|
Wed May 7 19:05:08 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 04/04 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 27.8 nA
Ibias (200 V) = 32.7 nA |
12x |
|
12
|
Fri May 9 10:00:34 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 03/10 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 18.9 nA
Ibias (200 V) = 25.5 nA |
12x |
|
5
|
Wed Apr 30 16:52:17 2008 |
Markus Friedl | BELLE Upgrade | module | micron | micron sensor glued to frame | soeben haben wir den micron-DSSD (double metal
layer) in den 2-teiligen rahmen geklebt und
auf beiden seiten
|
|
|
14
|
Tue May 20 14:27:50 2008 |
Markus Friedl | BELLE Upgrade | source | micron | analysis results of source test |
*** NOTE: AFTER THIS MEASUREMENT WE REALIZED
THAT BIASING WAS NOT DONE PROPERLY
|
9x |
|
1
|
Fri Apr 18 17:23:26 2008 |
Markus Friedl | SPS Testbeam June08 | hybrid | hybrid 01 | Noise of hybrid 01, sensor fully bonded, no HV | HV bias not yet glued to backplane |
|
|
2
|
Tue Apr 22 19:34:09 2008 |
Markus Friedl | SPS Testbeam June08 | module | hybrid 01 | Properties of hybrid 01, sensor fully bonded, HV=100V | HV bias glued to backplane, HV=100V |
6x |
|
3
|
Wed Apr 23 13:05:05 2008 |
Christian Irmler | SPS Testbeam June08 | source | hybrid 01 | time correlation between TDC and sensor measurement -> 3.1 ns RMS | |
|
|
4
|
Wed Apr 23 13:37:18 2008 |
Markus Friedl | SPS Testbeam June08 | source | hybrid 01 | analysis results of source test | Ignore the "KEK November 2007" title - that's
a legacy and is already changed :-)
|
|
|
33
|
Thu Jun 5 10:33:46 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 1° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
34
|
Thu Jun 5 10:34:06 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 4° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
35
|
Thu Jun 5 10:34:29 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 7° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
36
|
Thu Jun 5 10:34:45 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 10° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
59
|
Mon Nov 30 18:45:49 2015 |
Hao Yin | Belle II | system | PedestalRun_Cold | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
|
|
|
54
|
Mon Nov 30 17:13:47 2015 |
Hao Yin | Belle II | system | PedestalRun | | ADC Hot, FIRRun001
room temp pedrun |
|