Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in October 2024, Page 7 of 29  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Biasing Beam Energy thr HV scan-valdown Data t-Start t-Stop Duration_min
  76   Wed Oct 2 17:02:43 2024 tb-crewmanual HV scan67V W3-1E14Backside4.21.1-290 Unknown02.10.2024 16:53:0602.10.2024 17:03:0910
automatic log for run 67
Comment:
-500V no problem, current 30uA
  77   Wed Oct 2 17:13:18 2024 tb-crewmanual HV scan68V W3-1E14Backside4.21.1-340 Unknown02.10.2024 17:03:4102.10.2024 17:13:4410
automatic log for run 68
Comment:
-500V no problem, current 30uA
  78   Wed Oct 2 17:23:54 2024 tb-crewmanual HV scan69V W3-1E14Backside4.21.1-390 Unknown02.10.2024 17:14:1702.10.2024 17:24:2010
automatic log for run 69
Comment:
-500V no problem, current 30uA
  79   Wed Oct 2 17:34:31 2024 tb-crewmanual HV scan70V W3-1E14Backside4.21.1-440 Unknown02.10.2024 17:24:5402.10.2024 17:34:5710
automatic log for run 70
Comment:
-500V no problem, current 30uA
  80   Wed Oct 2 17:40:36 2024 tb-crewmanual HV scan71V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:35:3102.10.2024 17:41:025
automatic log for run 71
Comment:
-500V no problem, current 30uA
  81   Wed Oct 2 17:43:57 2024 tb-crewTP ROI fidling around72V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:42:1602.10.2024 17:44:232
automatic log for run 72
Comment:
  82   Wed Oct 2 17:46:21 2024 tb-crewTP ROI fidling around73V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:44:3902.10.2024 17:46:462
automatic log for run 73
Comment:
  83   Wed Oct 2 17:48:26 2024 tb-crewTP ROI fidling around74V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:46:5802.10.2024 17:48:521
automatic log for run 74
Comment:
  84   Wed Oct 2 17:51:22 2024 tb-crewTP ROI fidling around75V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:49:0502.10.2024 17:51:472
automatic log for run 75
Comment:
  85   Wed Oct 2 17:53:01 2024 tb-crewTP ROI fidling around76V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:51:5802.10.2024 17:53:271
automatic log for run 76
Comment:
  86   Wed Oct 2 17:55:20 2024 tb-crewTP ROI fidling around77V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:54:0302.10.2024 17:55:461
automatic log for run 77
Comment:
  87   Wed Oct 2 18:09:02 2024 tb-crewHV final steps78V W3-1E14Backside4.21.1-490 Unknown02.10.2024 17:58:1702.10.2024 18:09:2811
automatic log for run 78
Comment:
  88   Wed Oct 2 18:19:53 2024 tb-crewHV final steps79V W3-1E14Backside4.21.1-600 Unknown02.10.2024 18:10:1002.10.2024 18:20:1910
automatic log for run 79
Comment:
38uA
  89   Wed Oct 2 22:08:10 2024 tb-crewthr minimizing80V W3-1E14Backside4.21.02-190 Unknown02.10.2024 22:03:4702.10.2024 22:08:364
automatic log for run 80
Comment:
  90   Wed Oct 2 22:10:53 2024 tb-crewthr minimizing81V W3-1E14Backside4.21.02-190 Unknown02.10.2024 22:11:1102.10.2024 22:11:180
automatic log for run 81
Comment:
  91   Wed Oct 2 22:11:02 2024 tb-crewthr minimizing V W3-1E14Backside4.21.02-190 Unknown   
that was noise
  92   Wed Oct 2 22:24:20 2024 tb-crewthr minimizing82V W3-1E14Backside4.21.05-600 Unknown02.10.2024 22:14:3402.10.2024 22:24:4610
automatic log for run 82
Comment:
really nice run
  93   Wed Oct 2 22:26:35 2024 tb-crew  V W3-1E14Topside4.21.05-600 Unknown   
put jumper to HV_SR position
  94   Wed Oct 2 22:50:58 2024 tb-crewHV scan 83V W3-1E14Topside4.21.05-500 Unknown02.10.2024 22:50:3402.10.2024 22:51:240
automatic log for run 83
Comment:
  95   Wed Oct 2 23:02:19 2024 tb-crewHV scan 84V W3-1E14Topside4.21.1-500 Unknown02.10.2024 22:52:4102.10.2024 23:02:4510
automatic log for run 84
Comment:
ELOG V3.1.5-fc6679b