Wed Oct 2 16:27:08 2024, tb-crew, manual HV scan, 61, V W3-1E14, Backside, 4.2, 1.1, -290, , Unknown, 02.10.2024 16:27:27, 02.10.2024 16:27:34, 0
|
automatic log for run 61
Comment:
trying manually to find scan limit |
Wed Oct 2 16:27:39 2024, tb-crew, manual HV scan, 62, V W3-1E14, Backside, 4.2, 1.1, -350, , Unknown, 02.10.2024 16:27:59, 02.10.2024 16:28:04, 0
|
automatic log for run 62
Comment:
trying manually to find scan limit |
Wed Oct 2 16:28:18 2024, tb-crew, manual HV scan, 63, V W3-1E14, Backside, 4.2, 1.1, -400, , Unknown, 02.10.2024 16:28:36, 02.10.2024 16:28:44, 0
|
automatic log for run 63
Comment:
trying manually to find scan limit |
Wed Oct 2 16:28:53 2024, tb-crew, manual HV scan, 64, V W3-1E14, Backside, 4.2, 1.1, -500, , Unknown, 02.10.2024 16:29:08, 02.10.2024 16:29:19, 0
|
automatic log for run 64
Comment:
trying manually to find scan limit |
Wed Oct 2 16:30:27 2024, tb-crew, manual HV scan, , V W3-1E14, Backside, 4.2, 1.1, -500, , Unknown, , ,
|
-500V no problem, current 30uA |
Wed Oct 2 16:41:34 2024, tb-crew, manual HV scan, 65, V W3-1E14, Backside, 4.2, 1.1, -190, , Unknown, 02.10.2024 16:31:57, 02.10.2024 16:42:00, 10
|
automatic log for run 65
Comment:
-500V no problem, current 30uA |
Wed Oct 2 16:52:08 2024, tb-crew, manual HV scan, 66, V W3-1E14, Backside, 4.2, 1.1, -240, , Unknown, 02.10.2024 16:42:31, 02.10.2024 16:52:34, 10
|
automatic log for run 66
Comment:
-500V no problem, current 30uA |
Wed Oct 2 17:02:43 2024, tb-crew, manual HV scan, 67, V W3-1E14, Backside, 4.2, 1.1, -290, , Unknown, 02.10.2024 16:53:06, 02.10.2024 17:03:09, 10
|
automatic log for run 67
Comment:
-500V no problem, current 30uA |
Wed Oct 2 17:13:18 2024, tb-crew, manual HV scan, 68, V W3-1E14, Backside, 4.2, 1.1, -340, , Unknown, 02.10.2024 17:03:41, 02.10.2024 17:13:44, 10
|
automatic log for run 68
Comment:
-500V no problem, current 30uA |
Wed Oct 2 17:23:54 2024, tb-crew, manual HV scan, 69, V W3-1E14, Backside, 4.2, 1.1, -390, , Unknown, 02.10.2024 17:14:17, 02.10.2024 17:24:20, 10
|
automatic log for run 69
Comment:
-500V no problem, current 30uA |
Wed Oct 2 17:34:31 2024, tb-crew, manual HV scan, 70, V W3-1E14, Backside, 4.2, 1.1, -440, , Unknown, 02.10.2024 17:24:54, 02.10.2024 17:34:57, 10
|
automatic log for run 70
Comment:
-500V no problem, current 30uA |
Wed Oct 2 17:40:36 2024, tb-crew, manual HV scan, 71, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:35:31, 02.10.2024 17:41:02, 5
|
automatic log for run 71
Comment:
-500V no problem, current 30uA |
Wed Oct 2 17:43:57 2024, tb-crew, TP ROI fidling around, 72, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:42:16, 02.10.2024 17:44:23, 2
|
automatic log for run 72
Comment: |
Wed Oct 2 17:46:21 2024, tb-crew, TP ROI fidling around, 73, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:44:39, 02.10.2024 17:46:46, 2
|
automatic log for run 73
Comment: |
Wed Oct 2 17:48:26 2024, tb-crew, TP ROI fidling around, 74, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:46:58, 02.10.2024 17:48:52, 1
|
automatic log for run 74
Comment: |
Wed Oct 2 17:51:22 2024, tb-crew, TP ROI fidling around, 75, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:49:05, 02.10.2024 17:51:47, 2
|
automatic log for run 75
Comment: |
Wed Oct 2 17:53:01 2024, tb-crew, TP ROI fidling around, 76, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:51:58, 02.10.2024 17:53:27, 1
|
automatic log for run 76
Comment: |
Wed Oct 2 17:55:20 2024, tb-crew, TP ROI fidling around, 77, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:54:03, 02.10.2024 17:55:46, 1
|
automatic log for run 77
Comment: |
Wed Oct 2 18:09:02 2024, tb-crew, HV final steps, 78, V W3-1E14, Backside, 4.2, 1.1, -490, , Unknown, 02.10.2024 17:58:17, 02.10.2024 18:09:28, 11
|
automatic log for run 78
Comment: |
Wed Oct 2 18:19:53 2024, tb-crew, HV final steps, 79, V W3-1E14, Backside, 4.2, 1.1, -600, , Unknown, 02.10.2024 18:10:10, 02.10.2024 18:20:19, 10
|
automatic log for run 79
Comment:
38uA |
|