Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in October 2024
Not logged in
List
|
Find
|
Login
|
Help
Message ID:
305
Entry time:
Fri Oct 4 09:02:53 2024
Author:
tb-crew
Subject:
VNFB scan
Run Number:
274
DUT:
V W3-1E14
Biasing:
Backside
Beam Energy:
4.2
thr:
1.1
HV:
-500
scan-val:
40
Data:
Unknown
t-Start:
04.10.2024 08:53:16
t-Stop:
04.10.2024 09:03:20
Duration_min:
10
automatic log for run 274
Comment:
Attachment 1:
peary_config.cfg
1 kB
|
Show
|
Show all
Attachment 2:
matrix_mpw4_base.txt
274 Bytes
|
Show
|
Show all
Attachment 3:
default_1.conf
2 kB
|
Show
|
Show all
ELOG V3.1.5-fc6679b