Message ID:
254
Entry time:
Fri Oct 4 00:33:31 2024
Author:
tb-crew
Subject:
HV scan
Run Number:
226
DUT:
V W3-1E14
Biasing:
Backside
Beam Energy:
4.2
thr:
1.1
HV:
-420
scan-val:
Data:
Unknown
t-Start:
04.10.2024 00:23:55
t-Stop:
04.10.2024 00:33:58
Duration_min:
10
automatic log for run 226
Comment:
Attachment 1:
peary_config.cfg
1 kB
|
Show
|
Show all
Attachment 2:
matrix_mpw4_base.txt
274 Bytes
|
Show
|
Show all
Attachment 3:
default_8.conf
2 kB
|
Show
|
Show all
ELOG V3.1.5-fc6679b