Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Jul2025
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in July 2025, Page 9 of 17
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
W3-2 5E14
W3-4 1E15
W8-2 1E15
W3-5 2E15
W8-3 2E15
W3-7 3E15
W8-6 3E15
W3-8 5E15
W3-1 5E14
W3-3 1E15
W3-6 2E15
W3-1x3 3E15
W8-5 3E15
W11 5E15
W3 0E00
W8 0E00
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
321 Entries
Goto page
Previous
1
,
2
,
3
...
8
, 9,
10
...
15
,
16
,
17
Next
All
ID
Date
Author
Subject
Run Number
DUT
Biasing
Beam Energy
thr
HV
scan-val
Data
t-Start
t-Stop
Duration_min
Text
233
Thu Jul 3 17:59:26 2025
tb-crew
bias scan
212
W3-8 5E15
Topside
4.2
0.97
-25
Good
03.07.2025 17:59:16
03.07.2025 17:59:26
0
automatic log for run 212
Comment:
rerun bias scan with higher thr
234
Thu Jul 3 18:05:08 2025
tb-crew
bias scan
213
W3-8 5E15
Topside
4.2
0.97
-25
Good
03.07.2025 18:00:06
03.07.2025 18:05:09
5
automatic log for run 213
Comment:
rerun bias scan with higher thr
248
Thu Jul 3 21:48:17 2025
tb-crew
bias scan
225
W3-5 2E15
Backside
4.2
1.01
-25
Good
03.07.2025 21:43:15
03.07.2025 21:48:18
5
automatic log for run 225
Comment:
279
Fri Jul 4 10:20:54 2025
tb-crew
bias scan
W8-3 2E15
Topside
4.2
0.98
-25
Good
was actually a thr scan, my fault sry
280
Fri Jul 4 10:26:01 2025
tb-crew
bias scan
258
W8-3 2E15
Topside
4.2
0.98
-25
Good
04.07.2025 10:20:59
04.07.2025 10:26:02
5
automatic log for run 258
Comment:
85
Wed Jul 2 11:22:23 2025
tb-crew
dry bias scan
75
W3-2 5E14
Backside
4.2
0.99
-225
Unknown
02.07.2025 11:22:41
02.07.2025 11:22:50
0
automatic log for run 75
Comment:
no beam atm (Machine State = studies)
95
Wed Jul 2 11:44:40 2025
tb-crew
dry bias scan
85
W3-2 5E14
Backside
4.2
0.99
-225
Unknown
02.07.2025 11:44:58
02.07.2025 11:45:07
0
automatic log for run 85
Comment:
122
Wed Jul 2 17:13:08 2025
tb-crew
bias scan
109
W3-2 5E14
Backside
4.2
0.99
-225
Good
02.07.2025 17:12:59
02.07.2025 17:13:36
0
automatic log for run 109
Comment:
error
124
Wed Jul 2 17:20:36 2025
tb-crew
bias scan
110
W3-2 5E14
Backside
4.2
0.99
-225
Good
02.07.2025 17:20:40
02.07.2025 17:21:04
0
automatic log for run 110
Comment:
125
Wed Jul 2 17:39:16 2025
tb-crew
bias scan
111
W3-2 5E14
Backside
4.2
0.99
-225
Good
02.07.2025 17:29:39
02.07.2025 17:39:43
10
automatic log for run 111
Comment:
152
Thu Jul 3 00:47:34 2025
tb-crew
bias scan
136
W8-2 1E15
Topside
4.2
0.94
-225
Good
03.07.2025 00:37:58
03.07.2025 00:48:02
10
automatic log for run 136
Comment:
298
Fri Jul 4 11:25:44 2025
tb-crew
test
273
W8-3 2E15
Topside
4.2
0.98
-225
Good
04.07.2025 11:25:36
04.07.2025 11:25:46
0
automatic log for run 273
Comment:
more like at 225V
84
Wed Jul 2 11:21:43 2025
tb-crew
dry bias scan
74
W3-2 5E14
Backside
4.2
0.99
-200
Unknown
02.07.2025 11:22:01
02.07.2025 11:22:10
0
automatic log for run 74
Comment:
no beam atm (Machine State = studies)
94
Wed Jul 2 11:44:01 2025
tb-crew
dry bias scan
84
W3-2 5E14
Backside
4.2
0.99
-200
Unknown
02.07.2025 11:44:19
02.07.2025 11:44:28
0
automatic log for run 84
Comment:
121
Wed Jul 2 17:11:57 2025
tb-crew
bias scan
108
W3-2 5E14
Backside
4.2
0.99
-200
Good
02.07.2025 17:02:20
02.07.2025 17:12:24
10
automatic log for run 108
Comment:
151
Thu Jul 3 00:36:54 2025
tb-crew
bias scan
135
W8-2 1E15
Topside
4.2
0.94
-200
Good
03.07.2025 00:27:18
03.07.2025 00:37:22
10
automatic log for run 135
Comment:
203
Thu Jul 3 15:29:45 2025
tb-crew
bias scan
W3-8 5E15
Topside
4.2
0.96
-200
Good
increased compliance to 200uA
204
Thu Jul 3 15:31:05 2025
tb-crew
bias scan
180
W3-8 5E15
Topside
4.2
0.96
-200
Good
03.07.2025 15:27:22
03.07.2025 15:31:33
4
automatic log for run 180
Comment:
hit compliance, abort scan
206
Thu Jul 3 15:40:36 2025
tb-crew
bias scan
182
W3-8 5E15
Topside
4.2
0.96
-200
Good
03.07.2025 15:36:00
03.07.2025 15:41:04
5
automatic log for run 182
Comment:
239
Thu Jul 3 18:33:20 2025
tb-crew
bias scan
218
W3-8 5E15
Topside
4.2
0.97
-200
Good
03.07.2025 18:28:18
03.07.2025 18:33:21
5
automatic log for run 218
Comment:
rerun bias scan with higher thr
Goto page
Previous
1
,
2
,
3
...
8
, 9,
10
...
15
,
16
,
17
Next
All
ELOG V3.1.5-fc6679b