testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 7 of 12  Not logged in ELOG logo
ID Date Author Subjectdown Run Number DUT Biasing Beam Energy thr HV scan-val Data t-Start t-Stop Duration_min
  208   Thu Jul 3 15:51:53 2025 tb-crewbias scan184W3-8 5E15Topside4.20.96-300 Good03.07.2025 15:47:1803.07.2025 15:52:215
automatic log for run 184
Comment:
  209   Thu Jul 3 15:57:32 2025 tb-crewbias scan185W3-8 5E15Topside4.20.96-350 Good03.07.2025 15:52:5703.07.2025 15:58:005
automatic log for run 185
Comment:
  210   Thu Jul 3 15:58:22 2025 tb-crewbias scan186W3-8 5E15Topside4.20.96-400 Good03.07.2025 15:58:3603.07.2025 15:58:500
automatic log for run 186
Comment:
  211   Thu Jul 3 15:58:34 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-400 Good   
hit compliance at 400V
  212   Thu Jul 3 16:08:51 2025 tb-crewbias scan187W3-8 5E15Topside4.20.96-50 Good03.07.2025 16:09:1103.07.2025 16:09:190
automatic log for run 187
Comment:
  213   Thu Jul 3 16:10:37 2025 tb-crewbias scan188W3-8 5E15Topside4.20.96-350 Good03.07.2025 16:10:1203.07.2025 16:11:050
automatic log for run 188
Comment:
resume from 350V
  214   Thu Jul 3 16:11:34 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-350 Good   
can't set compliance to values > 200uA via producer, trying manually now
  215   Thu Jul 3 16:22:15 2025 tb-crewbias scan190W3-8 5E15Topside4.20.96-50 Good03.07.2025 16:22:3703.07.2025 16:22:430
automatic log for run 190
Comment:
  216   Thu Jul 3 16:28:08 2025 tb-crewbias scan191W3-8 5E15Topside4.20.96-350 Good03.07.2025 16:23:3203.07.2025 16:28:365
automatic log for run 191
Comment:
  217   Thu Jul 3 16:33:34 2025 tb-crewbias scan192W3-8 5E15Topside4.20.96-400 Good03.07.2025 16:29:1203.07.2025 16:34:024
automatic log for run 192
Comment:
dominated by noise at this point
  218   Thu Jul 3 16:34:56 2025 tb-crewbias scan W3-8 5E15Topside4.21.1-400 Good   
increased threshold
  219   Thu Jul 3 16:39:57 2025 tb-crewbias scan193W3-8 5E15Topside4.21.1-400 Good03.07.2025 16:35:2103.07.2025 16:40:255
automatic log for run 193
Comment:
  220   Thu Jul 3 16:45:35 2025 tb-crewbias scan194W3-8 5E15Topside4.21.1-450 Good03.07.2025 16:41:0003.07.2025 16:46:035
automatic log for run 194
Comment:
  229   Thu Jul 3 17:44:29 2025 tb-crewbias scan W3-8 5E15Topside4.21.09-400 Good   
rerun bias scan with increased thr (hopefully no noise)
400V at thr = 970mV yielded 24% effi
  230   Thu Jul 3 17:45:30 2025 tb-crewbias scan207W3-8 5E15Topside4.20.97-400 Good03.07.2025 17:45:4303.07.2025 17:45:580
automatic log for run 207
Comment:
rerun bias scan with increased thr (hopefully no noise)
  231   Thu Jul 3 17:52:14 2025 tb-crewbias scan209W3-8 5E15Topside4.20.97-100 Good03.07.2025 17:52:3403.07.2025 17:52:420
automatic log for run 209
Comment:
  163   Thu Jul 3 07:25:24 2025 tb-crew thr scan147W8-2 1E15Topside4.20.94-400 Good03.07.2025 07:25:4103.07.2025 07:25:520
automatic log for run 147
Comment:
  164   Thu Jul 3 07:26:58 2025 tb-crew thr scan148W8-2 1E15Topside4.20.95-400 Good03.07.2025 07:26:3203.07.2025 07:27:260
automatic log for run 148
Comment:
  165   Thu Jul 3 07:38:23 2025 tb-crew thr scan149W8-2 1E15Topside4.20.92-400 Good03.07.2025 07:28:4803.07.2025 07:38:5110
automatic log for run 149
Comment:
  166   Thu Jul 3 07:49:02 2025 tb-crew thr scan150W8-2 1E15Topside4.20.93-400 Good03.07.2025 07:39:2703.07.2025 07:49:3010
automatic log for run 150
Comment: