testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 6 of 27  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subjectdown Run Number DUT Biasing Beam Energy thr HV scan-val Data t-Start t-Stop Duration_min
  295   Fri Jul 4 11:23:57 2025 tb-crewtest271W8-3 2E15Topside4.20.98-250 Good04.07.2025 11:23:5304.07.2025 11:23:580
automatic log for run 271
Comment:
breakdown at ~300V
  296   Fri Jul 4 11:24:08 2025 tb-crewtest W8-3 2E15Topside4.20.98-250 Good   
more like at 250V
  297   Fri Jul 4 11:24:47 2025 tb-crewtest272W8-3 2E15Topside4.20.98-200 Good04.07.2025 11:24:4304.07.2025 11:24:480
automatic log for run 272
Comment:
more like at 250V
  298   Fri Jul 4 11:25:44 2025 tb-crewtest273W8-3 2E15Topside4.20.98-225 Good04.07.2025 11:25:3604.07.2025 11:25:460
automatic log for run 273
Comment:
more like at 225V
  299   Fri Jul 4 11:26:37 2025 tb-crewtest274W8-3 2E15Topside4.20.98-200 Good04.07.2025 11:26:2904.07.2025 11:26:380
automatic log for run 274
Comment:
more like at 225V
  300   Fri Jul 4 11:28:11 2025 tb-crewtest275W8-3 2E15Topside4.20.98-190 Good04.07.2025 11:28:0704.07.2025 11:28:130
automatic log for run 275
Comment:
more like at 225V
  301   Fri Jul 4 11:28:56 2025 tb-crewtest276W8-3 2E15Topside4.20.98-190 Good04.07.2025 11:28:3804.07.2025 11:28:570
automatic log for run 276
Comment:
more like at 225V
  302   Fri Jul 4 11:29:35 2025 tb-crewtest277W8-3 2E15Topside4.20.98-190 Good04.07.2025 11:29:3304.07.2025 11:29:370
automatic log for run 277
Comment:
more like at 225V
  303   Fri Jul 4 11:30:35 2025 tb-crewtest278W8-3 2E15Topside4.20.98-150 Good04.07.2025 11:30:2704.07.2025 11:30:360
automatic log for run 278
Comment:
more like at 160
  304   Fri Jul 4 11:34:43 2025 tb-crewtest W8-3 2E15Topside4.20.98-150 Good   
cant go higher than 150V without hitting compliance
  319   Fri Jul 4 13:29:18 2025 tb-crewtest292W3-7 3E15Backside4.21.00-50 Good04.07.2025 13:28:3504.07.2025 13:29:190
automatic log for run 292
Comment:
  320   Fri Jul 4 13:32:40 2025 tb-crewtest W3-7 3E15Backside4.21.00-50 Good   
that was plain noise
  321   Fri Jul 4 13:33:50 2025 tb-crewtest293W3-7 3E15Backside4.21.00-50 Good04.07.2025 13:33:0004.07.2025 13:33:520
automatic log for run 293
Comment:
  322   Fri Jul 4 13:37:33 2025 tb-crewtest294W3-7 3E15Backside4.21.00-50 Good04.07.2025 13:37:0104.07.2025 13:37:350
automatic log for run 294
Comment:
  323   Fri Jul 4 13:39:15 2025 tb-crewtest295W3-7 3E15Backside4.21.00-50 Good04.07.2025 13:38:4004.07.2025 13:39:160
automatic log for run 295
Comment:
  324   Fri Jul 4 13:39:56 2025 tb-crewtest W3-7 3E15Backside4.21.00-50 Good   
data related to particles on 2nd setup with thr = 1.0V
  325   Fri Jul 4 13:44:09 2025 tb-crewtest296W3-7 3E15Backside4.21.00-50 Good04.07.2025 13:40:0204.07.2025 13:44:104
automatic log for run 296
Comment:
data related to particles on 2nd setup with thr = 1.0V
  326   Fri Jul 4 13:54:01 2025 tb-crewtest297W3-7 3E15Backside4.21.00-50 Good04.07.2025 13:44:5104.07.2025 13:54:029
automatic log for run 297
Comment:
data related to particles on 2nd setup with thr = 1.0V
  327   Fri Jul 4 13:58:08 2025 tb-crewtest298W3-7 3E15Backside4.21.02-50 Good04.07.2025 13:57:4704.07.2025 13:58:100
automatic log for run 298
Comment:
  328   Fri Jul 4 14:01:44 2025 tb-crewtest299W3-7 3E15Backside4.21.02-50 Good04.07.2025 14:01:1204.07.2025 14:01:450
automatic log for run 299
Comment:
noisy, trying to find proper thr