testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 4 of 14  Not logged in ELOG logo
IDdown Date Author Subject Run Number DUT Biasing Beam Energy thr HV scan-val Data t-Start t-Stop Duration_min
  213   Thu Jul 3 16:10:37 2025 tb-crewbias scan188W3-8 5E15Topside4.20.96-350 Good03.07.2025 16:10:1203.07.2025 16:11:050
automatic log for run 188
Comment:
resume from 350V
  212   Thu Jul 3 16:08:51 2025 tb-crewbias scan187W3-8 5E15Topside4.20.96-50 Good03.07.2025 16:09:1103.07.2025 16:09:190
automatic log for run 187
Comment:
  211   Thu Jul 3 15:58:34 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-400 Good   
hit compliance at 400V
  210   Thu Jul 3 15:58:22 2025 tb-crewbias scan186W3-8 5E15Topside4.20.96-400 Good03.07.2025 15:58:3603.07.2025 15:58:500
automatic log for run 186
Comment:
  209   Thu Jul 3 15:57:32 2025 tb-crewbias scan185W3-8 5E15Topside4.20.96-350 Good03.07.2025 15:52:5703.07.2025 15:58:005
automatic log for run 185
Comment:
  208   Thu Jul 3 15:51:53 2025 tb-crewbias scan184W3-8 5E15Topside4.20.96-300 Good03.07.2025 15:47:1803.07.2025 15:52:215
automatic log for run 184
Comment:
  207   Thu Jul 3 15:46:15 2025 tb-crewbias scan183W3-8 5E15Topside4.20.96-250 Good03.07.2025 15:41:3903.07.2025 15:46:435
automatic log for run 183
Comment:
  206   Thu Jul 3 15:40:36 2025 tb-crewbias scan182W3-8 5E15Topside4.20.96-200 Good03.07.2025 15:36:0003.07.2025 15:41:045
automatic log for run 182
Comment:
  205   Thu Jul 3 15:32:40 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-400 Good   
restart from -200V
  204   Thu Jul 3 15:31:05 2025 tb-crewbias scan180W3-8 5E15Topside4.20.96-200 Good03.07.2025 15:27:2203.07.2025 15:31:334
automatic log for run 180
Comment:
hit compliance, abort scan
  203   Thu Jul 3 15:29:45 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-200 Good   
increased compliance to 200uA
  202   Thu Jul 3 15:26:18 2025 tb-crewbias scan179W3-8 5E15Topside4.20.96-150 Good03.07.2025 15:21:4303.07.2025 15:26:465
automatic log for run 179
Comment:
changed scan time to 5 min
  201   Thu Jul 3 15:20:40 2025 tb-crewbias scan178W3-8 5E15Topside4.20.96-100 Good03.07.2025 15:16:0503.07.2025 15:21:085
automatic log for run 178
Comment:
changed scan time to 5 min
  200   Thu Jul 3 15:15:02 2025 tb-crewbias scan177W3-8 5E15Topside4.20.96-75 Good03.07.2025 15:10:2703.07.2025 15:15:305
automatic log for run 177
Comment:
changed scan time to 5 min
  199   Thu Jul 3 15:09:24 2025 tb-crewbias scan176W3-8 5E15Topside4.20.96-50 Good03.07.2025 15:04:4903.07.2025 15:09:525
automatic log for run 176
Comment:
changed scan time to 5 min
  198   Thu Jul 3 15:03:03 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-25 Good   
changed scan time to 5 min
  197   Thu Jul 3 15:02:48 2025 tb-crewbias scan175W3-8 5E15Topside4.20.96-25 Good03.07.2025 15:01:0503.07.2025 15:03:162
automatic log for run 175
Comment:
changed thr to reduce noise
  196   Thu Jul 3 14:59:49 2025 tb-crewbias scan W3-8 5E15Topside4.20.95-25 Good   
changed thr to reduce noise
  195   Thu Jul 3 14:58:54 2025 tb-crewbias scan174W3-8 5E15Topside4.20.95-25 Good03.07.2025 14:49:1903.07.2025 14:59:2210
automatic log for run 174
Comment:
  194   Thu Jul 3 14:57:35 2025 tb-crewbias scan W3-8 5E15Topside4.20.95-25 Good   
chip seems noisy, no good Correlations