testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 23 of 24  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Biasing Beam Energy thr HVdown scan-val Data t-Start t-Stop Duration_min
  147   Wed Jul 2 23:54:20 2025 tb-crew bias scan131W8-2 1E15Topside4.20.94-100 Good02.07.2025 23:44:4502.07.2025 23:54:4810
automatic log for run 131
Comment:
  201   Thu Jul 3 15:20:40 2025 tb-crewbias scan178W3-8 5E15Topside4.20.96-100 Good03.07.2025 15:16:0503.07.2025 15:21:085
automatic log for run 178
Comment:
changed scan time to 5 min
  231   Thu Jul 3 17:52:14 2025 tb-crewbias scan209W3-8 5E15Topside4.20.97-100 Good03.07.2025 17:52:3403.07.2025 17:52:420
automatic log for run 209
Comment:
  237   Thu Jul 3 18:22:04 2025 tb-crewbias scan216W3-8 5E15Topside4.20.97-100 Good03.07.2025 18:17:0203.07.2025 18:22:055
automatic log for run 216
Comment:
rerun bias scan with higher thr
  251   Thu Jul 3 22:05:17 2025 tb-crewbias scan228W3-5 2E15Backside4.21.01-100 Good03.07.2025 22:00:1503.07.2025 22:05:185
automatic log for run 228
Comment:
  283   Fri Jul 4 10:42:55 2025 tb-crewbias scan261W8-3 2E15Topside4.20.98-100 Good04.07.2025 10:37:5304.07.2025 10:42:565
automatic log for run 261
Comment:
  339   Fri Jul 4 14:31:17 2025 tb-crewbias scan308W3-7 3E15Backside4.21.05-100 Good04.07.2025 14:26:1504.07.2025 14:31:185
automatic log for run 308
Comment:
  400   Sat Jul 5 07:47:01 2025 tb-crewbias scan364W3-4 1E15Topside4.20.94-100 Good05.07.2025 07:40:5705.07.2025 07:47:036
automatic log for run 364
Comment:
manually run missed voltage
  446   Sat Jul 5 16:02:59 2025 tb-crewdeath scan402W3-8 5E15Backside4.21.05-100 Good05.07.2025 15:57:5705.07.2025 16:03:015
automatic log for run 402
Comment:
  76   Wed Jul 2 11:16:25 2025 tb-crewdry bias scan66W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 11:16:4402.07.2025 11:16:520
automatic log for run 66
Comment:
no beam atm (Machine State = studies)
  86   Wed Jul 2 11:38:45 2025 tb-crewdry bias scan76W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 11:39:0402.07.2025 11:39:120
automatic log for run 76
Comment:
  99   Wed Jul 2 14:05:23 2025 tb-crew bias scan88W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 14:05:2002.07.2025 14:05:500
automatic log for run 88
Comment:
  100   Wed Jul 2 14:23:42 2025 tb-crew bias scan90W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 14:14:0502.07.2025 14:24:0910
automatic log for run 90
Comment:
  111   Wed Jul 2 15:36:39 2025 tb-crew bias scan W3-2 5E14Backside4.20.99-0 Unknown   
rerun bias scan with proper ROI
  112   Wed Jul 2 15:46:47 2025 tb-crew bias scan100W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 15:37:1102.07.2025 15:47:1410
automatic log for run 100
Comment:
  142   Wed Jul 2 23:04:15 2025 tb-crew bias scan127W8-2 1E15Topside4.20.94-0 Good02.07.2025 22:54:3902.07.2025 23:04:4210
automatic log for run 127
Comment:
overnight scan
  143   Wed Jul 2 23:05:09 2025 tb-crew bias scan W8-2 1E15Topside4.20.94-0 Good   
increasing N2 flow due to high humidity in our setup (Hamburg is humid these days)
  1   Thu Jun 26 08:33:52 2025 tb-crewtest W3-6 2E15Backside6.0   Crap   
test manual
  5   Mon Jun 30 17:32:39 2025 tb-crewtest W3 0E00Backside4.2   Crap   
1st log from hut TB22
  28   Tue Jul 1 09:18:15 2025 tb-crewsystem test W3 0E00Backside4.2   Crap   
changed alignment of DUT