Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 22 of 23  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Biasing Beam Energy thr HV scan-val Data t-Start t-Stop Duration_mindown
  229   Thu Jul 3 17:44:29 2025 tb-crewbias scan W3-8 5E15Topside4.21.09-400 Good   
rerun bias scan with increased thr (hopefully no noise)
400V at thr = 970mV yielded 24% effi
  246   Thu Jul 3 21:06:35 2025 tb-crewbias scan W3-8 5E15Topside4.20.97-500 Good   
changing DUT now
  247   Thu Jul 3 21:07:09 2025 tb-crewbias scan W3-5 2E15Topside4.20.97-500 Good   
changing DUT now
  274   Fri Jul 4 09:04:59 2025 tb-crewthr scan W3-5 2E15Backside4.21.1-400 Good   
another day in the hut <3
  275   Fri Jul 4 10:04:07 2025 tb-crewROI test W8-3 2E15Backside4.20.98-50 Good   
changed DUT
  279   Fri Jul 4 10:20:54 2025 tb-crewbias scan W8-3 2E15Topside4.20.98-25 Good   
was actually a thr scan, my fault sry
  289   Fri Jul 4 11:16:16 2025 tb-crewbias scan W8-3 2E15Topside4.20.98-400 Good   
hit compliance
  293   Fri Jul 4 11:23:13 2025 tb-crewtest W8-3 2E15Topside4.20.98-200 Good   
breakdown at ~300V
  296   Fri Jul 4 11:24:08 2025 tb-crewtest W8-3 2E15Topside4.20.98-250 Good   
more like at 250V
  304   Fri Jul 4 11:34:43 2025 tb-crewtest W8-3 2E15Topside4.20.98-150 Good   
cant go higher than 150V without hitting compliance
  306   Fri Jul 4 11:37:49 2025 tb-crewthr scan W8-3 2E15Topside4.20.96-150 Good   
no TP triggers
  318   Fri Jul 4 13:28:25 2025 tb-crewthr scan W3-7 3E15Backside4.20.99-50 Good   
changed DUT
  320   Fri Jul 4 13:32:40 2025 tb-crewtest W3-7 3E15Backside4.21.00-50 Good   
that was plain noise
  324   Fri Jul 4 13:39:56 2025 tb-crewtest W3-7 3E15Backside4.21.00-50 Good   
data related to particles on 2nd setup with thr = 1.0V
  334   Fri Jul 4 14:13:42 2025 tb-crewbias scan W3-7 3E15Backside4.21.05-50 Good   
stopped as TP making problems
  336   Fri Jul 4 14:14:25 2025 tb-crewbias scan W3-7 3E15Backside4.21.05-50 Good   
resume scan
  341   Fri Jul 4 14:36:03 2025 tb-crewbias scan W3-7 3E15Backside4.21.05-150 Good   
about to resume
  359   Fri Jul 4 17:37:54 2025 tb-crewthr scan W8-5 3E15Topside4.2   Good   
changed DUT
  385   Fri Jul 4 20:00:27 2025 tb-crewtest W3-4 1E15Topside4.21.1-400 Good   
changing DUT
  386   Fri Jul 4 23:26:06 2025 tb-crewbias scan W3-4 1E15Topside4.2   Good   
overnight here we come