Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 19 of 20  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Biasing Beam Energy thr HVdown scan-val Data t-Start t-Stop Duration_min
  117   Wed Jul 2 16:32:56 2025 tb-crew bias scan W3-2 5E14Backside4.20.99-125 Good   
conf_reg_ts_ctrl was set to 0 so far...
ts_mode = TLU has to be used for proper effi in this bias scan

changed to 4 now
  118   Wed Jul 2 16:40:00 2025 tb-crew bias scan105W3-2 5E14Backside4.20.99-125 Good02.07.2025 16:30:2402.07.2025 16:40:2710
automatic log for run 105
Comment:
  148   Thu Jul 3 00:04:58 2025 tb-crew bias scan132W8-2 1E15Topside4.20.94-125 Good02.07.2025 23:55:2303.07.2025 00:05:2610
automatic log for run 132
Comment:
  80   Wed Jul 2 11:19:04 2025 tb-crewdry bias scan70W3-2 5E14Backside4.20.99-100 Unknown02.07.2025 11:19:2202.07.2025 11:19:310
automatic log for run 70
Comment:
no beam atm (Machine State = studies)
  90   Wed Jul 2 11:41:22 2025 tb-crewdry bias scan80W3-2 5E14Backside4.20.99-100 Unknown02.07.2025 11:41:4002.07.2025 11:41:490
automatic log for run 80
Comment:
  104   Wed Jul 2 15:06:18 2025 tb-crew bias scan94W3-2 5E14Backside4.20.99-100 Unknown02.07.2025 14:56:4102.07.2025 15:06:4510
automatic log for run 94
Comment:
  108   Wed Jul 2 15:24:56 2025 tb-crew bias scan97W3-2 5E14Backside4.20.99-100 Unknown02.07.2025 15:24:1602.07.2025 15:25:231
automatic log for run 97
Comment:
ROI fiddling
  109   Wed Jul 2 15:27:28 2025 tb-crew bias scan98W3-2 5E14Backside4.20.99-100 Unknown02.07.2025 15:26:5502.07.2025 15:27:551
automatic log for run 98
Comment:
full Tp
  110   Wed Jul 2 15:32:34 2025 tb-crew bias scan99W3-2 5E14Backside4.20.99-100 Unknown02.07.2025 15:32:3402.07.2025 15:33:010
automatic log for run 99
Comment:
ROI fiddling
  116   Wed Jul 2 16:29:22 2025 tb-crew bias scan104W3-2 5E14Backside4.20.99-100 Good02.07.2025 16:19:4602.07.2025 16:29:4910
automatic log for run 104
Comment:
  147   Wed Jul 2 23:54:20 2025 tb-crew bias scan131W8-2 1E15Topside4.20.94-100 Good02.07.2025 23:44:4502.07.2025 23:54:4810
automatic log for run 131
Comment:
  201   Thu Jul 3 15:20:40 2025 tb-crewbias scan178W3-8 5E15Topside4.20.96-100 Good03.07.2025 15:16:0503.07.2025 15:21:085
automatic log for run 178
Comment:
changed scan time to 5 min
  231   Thu Jul 3 17:52:14 2025 tb-crewbias scan209W3-8 5E15Topside4.20.97-100 Good03.07.2025 17:52:3403.07.2025 17:52:420
automatic log for run 209
Comment:
  237   Thu Jul 3 18:22:04 2025 tb-crewbias scan216W3-8 5E15Topside4.20.97-100 Good03.07.2025 18:17:0203.07.2025 18:22:055
automatic log for run 216
Comment:
rerun bias scan with higher thr
  251   Thu Jul 3 22:05:17 2025 tb-crewbias scan228W3-5 2E15Backside4.21.01-100 Good03.07.2025 22:00:1503.07.2025 22:05:185
automatic log for run 228
Comment:
  283   Fri Jul 4 10:42:55 2025 tb-crewbias scan261W8-3 2E15Topside4.20.98-100 Good04.07.2025 10:37:5304.07.2025 10:42:565
automatic log for run 261
Comment:
  339   Fri Jul 4 14:31:17 2025 tb-crewbias scan308W3-7 3E15Backside4.21.05-100 Good04.07.2025 14:26:1504.07.2025 14:31:185
automatic log for run 308
Comment:
  76   Wed Jul 2 11:16:25 2025 tb-crewdry bias scan66W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 11:16:4402.07.2025 11:16:520
automatic log for run 66
Comment:
no beam atm (Machine State = studies)
  86   Wed Jul 2 11:38:45 2025 tb-crewdry bias scan76W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 11:39:0402.07.2025 11:39:120
automatic log for run 76
Comment:
  99   Wed Jul 2 14:05:23 2025 tb-crew bias scan88W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 14:05:2002.07.2025 14:05:500
automatic log for run 88
Comment:
ELOG V3.1.5-fc6679b