testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 19 of 20  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Biasing Beam Energy thr HV scan-val Data t-Start t-Stop Duration_mindown
  175   Thu Jul 3 09:00:53 2025 tb-crew thr scan W8-2 1E15Topside4.21-400 Good   
From run 156 on no trigger -> no telescope
  176   Thu Jul 3 09:06:09 2025 tb-crew thr scan W8-2 1E15Topside4.20.94-400 Good   
continuing from thr = 0.99V again
  178   Thu Jul 3 09:10:55 2025 tb-crew thr scan W8-2 1E15Topside4.20.99-400 Good   
no proper beam atm
  192   Thu Jul 3 14:46:26 2025 tb-crew thr scan W3-8 5E15Topside4.20.95-50 Good   
changed DUT
  194   Thu Jul 3 14:57:35 2025 tb-crewbias scan W3-8 5E15Topside4.20.95-25 Good   
chip seems noisy, no good Correlations
  196   Thu Jul 3 14:59:49 2025 tb-crewbias scan W3-8 5E15Topside4.20.95-25 Good   
changed thr to reduce noise
  198   Thu Jul 3 15:03:03 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-25 Good   
changed scan time to 5 min
  203   Thu Jul 3 15:29:45 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-200 Good   
increased compliance to 200uA
  205   Thu Jul 3 15:32:40 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-400 Good   
restart from -200V
  211   Thu Jul 3 15:58:34 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-400 Good   
hit compliance at 400V
  214   Thu Jul 3 16:11:34 2025 tb-crewbias scan W3-8 5E15Topside4.20.96-350 Good   
can't set compliance to values > 200uA via producer, trying manually now
  218   Thu Jul 3 16:34:56 2025 tb-crewbias scan W3-8 5E15Topside4.21.1-400 Good   
increased threshold
  229   Thu Jul 3 17:44:29 2025 tb-crewbias scan W3-8 5E15Topside4.21.09-400 Good   
rerun bias scan with increased thr (hopefully no noise)
400V at thr = 970mV yielded 24% effi
  246   Thu Jul 3 21:06:35 2025 tb-crewbias scan W3-8 5E15Topside4.20.97-500 Good   
changing DUT now
  247   Thu Jul 3 21:07:09 2025 tb-crewbias scan W3-5 2E15Topside4.20.97-500 Good   
changing DUT now
  274   Fri Jul 4 09:04:59 2025 tb-crewthr scan W3-5 2E15Backside4.21.1-400 Good   
another day in the hut <3
  275   Fri Jul 4 10:04:07 2025 tb-crewROI test W8-3 2E15Backside4.20.98-50 Good   
changed DUT
  279   Fri Jul 4 10:20:54 2025 tb-crewbias scan W8-3 2E15Topside4.20.98-25 Good   
was actually a thr scan, my fault sry
  289   Fri Jul 4 11:16:16 2025 tb-crewbias scan W8-3 2E15Topside4.20.98-400 Good   
hit compliance
  293   Fri Jul 4 11:23:13 2025 tb-crewtest W8-3 2E15Topside4.20.98-200 Good   
breakdown at ~300V