Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Jul2025 testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in July 2025, Page 14 of 14  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Biasing Beam Energy thr HVdown scan-val Data t-Start t-Stop Duration_min Text Attachments
  251   Thu Jul 3 22:05:17 2025 tb-crewbias scan228W3-5 2E15Backside4.21.01-100 Good03.07.2025 22:00:1503.07.2025 22:05:185automatic log for run 228
Comment:
 peary_config.cfgmatrix_mpw4_base.txtdefault_3.conf 
  76   Wed Jul 2 11:16:25 2025 tb-crewdry bias scan66W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 11:16:4402.07.2025 11:16:520automatic log for run 66
Comment:
no beam atm (Machine State = studies)
 peary_config.cfgmatrix_mpw4_base.txtdefault_0.conf 
  86   Wed Jul 2 11:38:45 2025 tb-crewdry bias scan76W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 11:39:0402.07.2025 11:39:120automatic log for run 76
Comment:
 peary_config.cfgmatrix_mpw4_base.txtdefault_0.conf 
  99   Wed Jul 2 14:05:23 2025 tb-crew bias scan88W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 14:05:2002.07.2025 14:05:500automatic log for run 88
Comment:
 peary_config.cfgmatrix_mpw4_base.txtdefault_0.conf 
  100   Wed Jul 2 14:23:42 2025 tb-crew bias scan90W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 14:14:0502.07.2025 14:24:0910automatic log for run 90
Comment:
 peary_config.cfgmatrix_mpw4_base.txtdefault_0.conf 
  111   Wed Jul 2 15:36:39 2025 tb-crew bias scan W3-2 5E14Backside4.20.99-0 Unknown   rerun bias scan with proper ROI   
  112   Wed Jul 2 15:46:47 2025 tb-crew bias scan100W3-2 5E14Backside4.20.99-0 Unknown02.07.2025 15:37:1102.07.2025 15:47:1410automatic log for run 100
Comment:
 peary_config.cfgmatrix_mpw4_base.txtdefault_0.conf 
  142   Wed Jul 2 23:04:15 2025 tb-crew bias scan127W8-2 1E15Topside4.20.94-0 Good02.07.2025 22:54:3902.07.2025 23:04:4210automatic log for run 127
Comment:
overnight scan
 peary_config.cfgmatrix_mpw4_base.txtdefault_0.conf 
  143   Wed Jul 2 23:05:09 2025 tb-crew bias scan W8-2 1E15Topside4.20.94-0 Good   increasing N2 flow due to high humidity in
our setup (Hamburg is humid these days)
  
  1   Thu Jun 26 08:33:52 2025 tb-crewtest W3-6 2E15Backside6.0   Crap   test manual   
  5   Mon Jun 30 17:32:39 2025 tb-crewtest W3 0E00Backside4.2   Crap   1st log from hut TB22   
  28   Tue Jul 1 09:18:15 2025 tb-crewsystem test W3 0E00Backside4.2   Crap   changed alignment of DUT   
  31   Tue Jul 1 11:11:54 2025 tb-crewsystem test W3 0E00Backside4.2   Unknown   changed CarBoard due to sync problems   
  65   Tue Jul 1 18:48:36 2025 tb-crewsystem test W8 0E00Backside4.2   Unknown   changed DUT - hoping for full efficiency with
sample not carrying thermocouple
  
  123   Wed Jul 2 17:19:39 2025 tb-crew bias scan W3-2 5E14Backside4.2   Good   continue at 225V   