52
|
Thu Nov 20 00:55:14 2014 |
Hao Yin | Belle SVD | HardwareRun_007 | | | | | Unknown | temp cooled see attachment
last noise run(007)
FIRRun_002 |
|
53
|
Thu Nov 20 10:22:17 2014 |
Markus Friedl | Belle SVD | common | | | | | Unknown |
Some VME errors occured over
night
Optical fiber
changed
Situation |
|
55
|
Thu Nov 20 10:39:11 2014 |
Benedikt Würkner | Belle SVD | PedestalRun_009 | | | | | Unknown | cooled see appendix (FIRRun003)
MaxEvents 10000
|
|
56
|
Thu Nov 20 10:39:13 2014 |
Benedikt Würkner | Belle SVD | PedestalRun_009 | | | | | Unknown | cooled see appendix (FIRRun003)
MaxEvents 10000
|
|
57
|
Thu Nov 20 10:41:54 2014 |
Benedikt Würkner | Belle SVD | CalibrationRun_005 | | | | | Unknown | cooled see appendix (FIRRun_003)
PedestalRun_009 |
|
64
|
Thu Nov 20 17:16:56 2014 |
Axel König | common | how to run the EUDAQ offline monitor | | | | | Unknown | YOU need
1.) Folder EUDAQ OFFLINE Monitor
2.) ROOT |
|
67
|
Thu Nov 20 22:12:21 2014 |
Axel König | common | SPS Logbook / SPS Online Monitor | | | | | Unknown | Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325
Monitor: http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1 |
|
78
|
Fri Nov 21 18:23:05 2014 |
Axel König | common | New Table Calibration | | | | | Unknown | Nach powercut musste der Tisch neu
kalibriert werden. Diese Neukalibration betrifft
alle Messungen ab den ersten Messungen vom |
|
79
|
Fri Nov 21 18:35:17 2014 |
Axel König | AIDA | Important: Dockbox Inverter! | | | | | Unknown | Alle AIDA runs vor run_007 hatten kein
Signal auf den Sensoren 5 und 6.
Grund: Inverter auf N Seite war im |
|
80
|
Fri Nov 21 19:05:27 2014 |
Hao Yin | Belle SVD | FIRRun_004 | | | Fri Nov 21 19:05:23 CET 2014 | | Unknown | New ADC delay scan. cooled, -25 temperature
|
|
81
|
Fri Nov 21 19:10:09 2014 |
Hao Yin | Belle SVD | CalibrationRun_006 | | | | | Unknown | cooled, latest ADC delay scan and FIRRun. |
|
83
|
Fri Nov 21 19:42:36 2014 |
Hao Yin | | HardwareRun_033 | | | | | Good | L6 are swapped, needs to be corrected later
in the offline analysis.
cooled at -25 |
|
92
|
Sat Nov 22 11:16:26 2014 |
Markus Friedl | Belle SVD | cooling | | | | | Unknown | Cooling box plant hung up (I2C error on
Alix, persistent after reboot)
Power-cycled cooling plant, now working |
|
96
|
Sat Nov 22 16:43:18 2014 |
Axel König | common | table, telescope and dut geometry | | | | | Unknown | geometry files |
   |
100
|
Sat Nov 22 19:29:40 2014 |
Axel König | AIDA | DUT Position | | | | | Unknown | |
|
109
|
Sun Nov 23 09:49:00 2014 |
Markus Friedl | Belle SVD | cooling | | | | | Unknown | Saturday evening, the cooling became unstable
which indicates the end of the CO2 supply,
possibly having a mixture of liquid and gas |
|
113
|
Sun Nov 23 12:39:45 2014 |
Axel König | common | PMT's of EUDET (Igor Rubinsky) | | | | | Unknown | Der zweite PM (entsprechend der Beamrichtung)
war von Anfang an nicht angeschlossen an
die TLU! Stattdessen war ein Atlas pixel |
|
115
|
Sun Nov 23 15:07:54 2014 |
Markus Friedl | Belle SVD | common | | | | | Unknown | Geometry setup of FW/BW:
(all dimensions are in mm and refer
to the sensor planes) |
|