Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 6 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Thu Nov 20 17:16:56 2014, Axel König, common, how to run the EUDAQ offline monitor, , , , , Unknown 
YOU need
1.) Folder EUDAQ OFFLINE Monitor
2.) ROOT
Entry  Thu Nov 20 22:11:06 2014, Hao Yin, Belle SVD, HardwareRun, 012, , , , Good 
cooled see appendix (FirRun003)

PedestalRun_009

multi 6 Raw Mode
Entry  Thu Nov 20 22:12:21 2014, Axel König, common, SPS Logbook / SPS Online Monitor, , , , , Unknown 
Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325
 
Monitor:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1
Entry  Fri Nov 21 01:43:54 2014, Axel König, AIDA, calibration run, AIDA_run001_calibration, , , , Unknown 
Calibration run with AIDA DUT.
Single hit
Entry  Fri Nov 21 18:23:05 2014, Axel König, common, New Table Calibration, , , , , Unknown 
 Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack.
Entry  Fri Nov 21 18:35:17 2014, Axel König, AIDA, Important: Dockbox Inverter!, , , , , Unknown 
Alle AIDA runs vor run_007 hatten kein Signal auf den Sensoren 5 und 6.
Grund: Inverter auf N Seite war im config file noch an (von Markus behoben). 
Runs vor 007 können noch verwendet werden obwohl sensoren 5 und 6 negative Events lieferten (kommt aber auf das negative Limit an). 
Entry  Fri Nov 21 19:05:27 2014, Hao Yin, Belle SVD, FIRRun_004, , , Fri Nov 21 19:05:23 CET 2014, , Unknown 
New ADC delay scan. cooled, -25 temperature
 
Entry  Fri Nov 21 19:10:09 2014, Hao Yin, Belle SVD, CalibrationRun_006, , , , , Unknown 
cooled, latest ADC delay scan and FIRRun. 
Entry  Fri Nov 21 19:42:36 2014, Hao Yin, , HardwareRun_033, , , , , Good Temp_21-11-14.PNG
L6 are swapped, needs to be corrected later in the offline analysis.

cooled at -25

latest ADC delay and FIRRun
Entry  Sat Nov 22 10:20:07 2014, Axel König, AIDA, calibration run, AIDA_calibration, , , , Unknown 
Calibration run AIDA_calibration 
L:\cern14\AIDA
Entry  Sat Nov 22 11:16:26 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown 
Cooling box plant hung up (I2C error on Alix, persistent after reboot)
Power-cycled cooling plant, now working
Slowly cooling down again
Entry  Sat Nov 22 16:04:05 2014, Axel König, Infineon, Infineon old calibration, Infineon_old_calibration, , , , Unknown 
Calibration run 
L:\cern14\infineon_old
Entry  Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown geometry_table.pdfgeometry_DUT.pdfgeometry_infineon_batch4.pdfgeometry_infineon_old.pdf
geometry files
Entry  Sat Nov 22 17:00:43 2014, Axel König, Infineon, Infineon old, damaged strixel sensors, strange IV behaviour, , , , Unknown 
1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.
2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 
Entry  Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown AIDA_DUT_Position.JPG
 
Entry  Sun Nov 23 09:49:00 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown temp_last_night.png
Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.
Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.
 
Entry  Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown 
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher
als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend
keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen
Entry  Sun Nov 23 15:07:54 2014, Markus Friedl, Belle SVD, common, , , , , Unknown fwbw_setup.png
Geometry setup of FW/BW:
(all dimensions are in mm and refer to the sensor planes)
ELOG V3.1.5-fc6679b