Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 5 of 6  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events StartTime EndTime Datadown
  92   Sat Nov 22 11:16:26 2014 Markus FriedlBelle SVDcooling    Unknown

Cooling box plant hung up (I2C error on Alix, persistent after reboot)

Power-cycled cooling plant, now working

Slowly cooling down again

  93   Sat Nov 22 11:37:16 2014 Benedikt WürknerBelle SVDHardwareRun0364503782014-11-22 1:00:002014-11-22 10:27:54Unknown

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

  94   Sat Nov 22 15:31:49 2014 Hao YinBelle SVDHardwareRun038437882014-11-22 15:18:40 Unknown

Cooled down to -20

Bias voltage set to +-60V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Zero suppressed

  95   Sat Nov 22 16:04:05 2014 Axel KönigInfineonInfineon old calibrationInfineon_old_calibration   Unknown

Calibration run 

L:\cern14\infineon_old

  96   Sat Nov 22 16:43:18 2014 Axel Königcommontable, telescope and dut geometry     Unknown

geometry files

  97   Sat Nov 22 16:53:39 2014 Axel KönigInfineonInfineon oldInfineon_old_run00155000   Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:97mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000992

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  98   Sat Nov 22 17:00:43 2014 Axel KönigInfineonInfineon olddamaged strixel sensors, strange IV behaviour   Unknown

1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.

2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 

  99   Sat Nov 22 18:08:03 2014 Axel KönigInfineonhardware runInfineon_old_run00255000  Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:102mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000993

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  100   Sat Nov 22 19:29:40 2014 Axel KönigAIDADUT Position    Unknown
  101   Sun Nov 23 00:20:41 2014 Axel KönigInfineonhardware runInfineon_old_run00330000  Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:?, H:?

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000994

DaqEvents: 30000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  102   Sun Nov 23 00:24:15 2014 Axel KönigInfineonhardware runInfineon_old_run004168725  Unknown

Infineon old

multi hit

Voltage=300V, I=10.6529uA

(new table calibration): V:81, H:88

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000996

DaqEvents: 168725 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  103   Sun Nov 23 00:51:07 2014 Axel KönigInfineonhardware runInfineon_old_run00526569  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4609uA

(new table calibration): V:75, H:94.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000997

DaqEvents: 26569 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

 
  106   Sun Nov 23 01:37:42 2014 Hao YinBelle SVDHardwareRun040200002014-11-23 01:37:00 Unknown

Bias voltage set to +-80V

Pedestal_015 (cooled)

"New" layout with no cooling (CO2 is no more)

Newly set values for APC Delay

New FIR Run 005

Temperature around 30 C

Bias: +-80V

  107   Sun Nov 23 09:32:48 2014 Axel KönigInfineonhardware runInfineon_old_run00763913  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:96.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000999

DaqEvents: 63913 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  108   Sun Nov 23 09:36:27 2014 Axel KönigInfineonhardware runInfineon_old_run006526562  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:95

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000998

DaqEvents: 526562 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  109   Sun Nov 23 09:49:00 2014 Markus FriedlBelle SVDcooling    Unknown

Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.

Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.

 

  110   Sun Nov 23 10:32:41 2014 Hao YinBelle SVDPedestalRun01610000  Unknown

Pedestal Run

room temperature (30C)

Bias scans planned

  111   Sun Nov 23 10:51:49 2014 Hao YinBelle SVDHardwareRun04276863  Unknown

Hardware Run +-40V Bias

Room Temperature

Pedestal 016

Zero Suppressed

  112   Sun Nov 23 12:17:59 2014 Benedikt WürknerBelle SVDHardwareRun04420000  Unknown

Hardware Run +-30V Bias

Room Temperature

Pedestal 017 (again marked all the bad strips)

Zero Suppressed

  113   Sun Nov 23 12:39:45 2014 Axel KönigcommonPMT's of EUDET (Igor Rubinsky)    Unknown

Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen).

ELOG V3.1.5-fc6679b