Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 2 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Project Subject Run Number Events StartTime EndTime Data
  100   Sat Nov 22 19:29:40 2014 Axel KönigAIDADUT Position    Unknown
Attachment 1: AIDA_DUT_Position.JPG
AIDA_DUT_Position.JPG
  99   Sat Nov 22 18:08:03 2014 Axel KönigInfineonhardware runInfineon_old_run00255000  Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:102mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000993

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  98   Sat Nov 22 17:00:43 2014 Axel KönigInfineonInfineon olddamaged strixel sensors, strange IV behaviour   Unknown

1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.

2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 

  97   Sat Nov 22 16:53:39 2014 Axel KönigInfineonInfineon oldInfineon_old_run00155000   Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:97mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000992

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  96   Sat Nov 22 16:43:18 2014 Axel Königcommontable, telescope and dut geometry     Unknown

geometry files

Attachment 1: geometry_table.pdf
Attachment 2: geometry_DUT.pdf
Attachment 3: geometry_infineon_batch4.pdf
Attachment 4: geometry_infineon_old.pdf
  95   Sat Nov 22 16:04:05 2014 Axel KönigInfineonInfineon old calibrationInfineon_old_calibration   Unknown

Calibration run 

L:\cern14\infineon_old

  94   Sat Nov 22 15:31:49 2014 Hao YinBelle SVDHardwareRun038437882014-11-22 15:18:40 Unknown

Cooled down to -20

Bias voltage set to +-60V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Zero suppressed

  93   Sat Nov 22 11:37:16 2014 Benedikt WürknerBelle SVDHardwareRun0364503782014-11-22 1:00:002014-11-22 10:27:54Unknown

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Attachment 1: SPS_Testbeam-Temp.xlsx
Attachment 2: Screen_Shot_2014-11-22_at_12.41.44.png
Screen_Shot_2014-11-22_at_12.41.44.png
  92   Sat Nov 22 11:16:26 2014 Markus FriedlBelle SVDcooling    Unknown

Cooling box plant hung up (I2C error on Alix, persistent after reboot)

Power-cycled cooling plant, now working

Slowly cooling down again

  91   Sat Nov 22 10:20:07 2014 Axel KönigAIDAcalibration runAIDA_calibration   Unknown

Calibration run AIDA_calibration 

L:\cern14\AIDA

  90   Sat Nov 22 07:56:33 2014 Axel KönigAIDAhardware runAIDA_run01355629  Unknown

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:45mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000990

DaqEvents: 55629 (-600 ped)

EUDAQ EVENTS: 55003 

 
  89   Sat Nov 22 00:58:04 2014 Axel KönigAIDAhardware runAIDA_run012276006  Unknown

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:70mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000989

DaqEvents: 276006 (-600 ped)

EUDAQ EVENTS: 275390 

  88   Sat Nov 22 00:11:36 2014 Axel KönigAIDAhardware runAIDA_run01124916  Unknown

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000988

DaqEvents: 24916 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

  87   Fri Nov 21 23:40:10 2014 Axel KönigAIDAhardware runAIDA_run01026329  Unknown

  

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:90mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000987

DaqEvents: 26329 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
  86   Fri Nov 21 23:34:36 2014 Axel KönigAIDAhardware runAIDA_run00932902  Unknown

 

AIDA

multi hit

Voltage=100V, I=5.2190uA

(new table calibration): V:71mm, H:100mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 32902 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
  85   Fri Nov 21 23:33:54 2014 Axel KönigAIDAhardware run (PC crashed)AIDA_run008---  Unknown

22:00 SVD3 PC crashed!!! data will be collected. 

  84   Fri Nov 21 22:08:32 2014 Hao Yin PedestalRun01310000  Unknown

correct mapping

cooled -25 °C

L3n deactivated

 

  83   Fri Nov 21 19:42:36 2014 Hao Yin HardwareRun_033    Good

L6 are swapped, needs to be corrected later in the offline analysis.

cooled at -25

latest ADC delay and FIRRun

PedestalRun_012

CalibrationRun_006

100k trigger dead time

 

Need to change L6n apv definition to:

mod = 9,0,1,1,1,m,29,0,0,0,0,0,0,L6_n_side

apv = 9,1,34,3,30,x,0,0,5,1,7,0,0,x
apv = 9,0,36,3,50,x,0,0,5,1,6,0,0,x
apv = 9,3,38,3,30,x,0,0,5,1,9,0,0,x
apv = 9,2,40,3,30,x,0,0,5,1,8,0,0,x

to  get the right mapping of the sensor.

Attachment 1: Temp_21-11-14.PNG
Temp_21-11-14.PNG
  82   Fri Nov 21 19:25:57 2014 Axel KönigAIDAhardware runAIDA_run00726770  Unknown

AIDA

multi hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:65mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 26770 (-600 ped)

EUDAQ EVENTS: 26171 (+1 trigger offset)

  81   Fri Nov 21 19:10:09 2014 Hao YinBelle SVDCalibrationRun_006    Unknown

cooled, latest ADC delay scan and FIRRun. 

ELOG V3.1.5-fc6679b