Message ID: 72     Entry time: Mon Feb 20 17:17:27 2012
Author: Christian Irmler 
Project: BELLE 
Subject: Origami Module #4 
Run Number: run100 
Events: 50k 
StartTime: 20.02.2012 17:07:21 
EndTime: 20.02.2012 17:17:22 
Data: Good 

Sr90, large scintillator, HVret @ Origami open
Origami Mod. #4
HV=+-40V, Ibias=2,03µA
CO2 cooling on, Tin=-16°C, Tout=-16,7°C

standard I²C settings for uncooled APV chips.

Lab measurement with new dark box but old, large scintillator.

20.02.2012  17:08:27  event=5771  ***WARNING*** Error detected in APV 6, subevent 0. Event discarded, reset sent. --> APV 6 recovered afterwards