Message ID: 36     Entry time: Wed Oct 5 19:33:40 2011
Author: Markus Friedl 
Project: common 
Subject: Trigger condition 
Run Number:  
Events:  
StartTime: 4.10.2011 15:00 
EndTime:  
Data:  

Changed trigger such that off-spill scintillator triggers are vetoed.

Inserted Flip-Flop which is set by begin of spill (WWE) and reset by end of spill signal (EE). Out-bar is put in coincidence with the scintillator trigger.

This also changes the timing, which was unfortunately not detected until 30 hours later. Thus, runs 4-7 have bad (wrong) timing -> UNUSABLE

Attachment 1: trigger_path_with_veto.png  389 kB  Uploaded Wed Oct 5 21:34:27 2011  | Hide | Hide all
trigger_path_with_veto.png