Entry  Thu Sep 23 16:00:31 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby2 -> TRACKING, , , ,  6x
p-side: Hybrid 46
alles ok
n-side: Hybrid 37
Entry  Thu Sep 23 15:54:20 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING, , , ,  6x
p-side: Hybrid 47
alles ok
n-side: Hybrid 38
Entry  Thu Sep 23 15:37:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate, , , ,  6x
p-side: Hybrid 48
alles ok
n-side: Hybrid 35 (wurde repariert, nachdem ein paar bonds dran glauben mussten...)
Entry  Thu Sep 23 15:32:28 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR, , , ,  6x
p-side: Hybrid 42
APV2: viele gerissene bonds der inneren Bondreihe
APV3: gerissene bonds innen
Entry  Wed Sep 15 10:25:13 2010, Marko Dragicevic, common, Equipment List, , , ,  
[B]Slow Control:[/B]
3x Source Measurement Unit Keithley K2410
-- Inv.Nr.: 540-702, 1000EUR