Message ID: 148     Entry time: Thu May 19 11:04:04 2011
Author: Manfred Valentan 
Project: Micron Baby 
Subject: DUT4, source run, irrad, postzupf 
Run Number: run119 
Events: 100k 
StartTime: 19.05.2011 10:08:14 
EndTime: 19.05.2011 10:29:02 

DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/postzupf/micronbaby_multi6_irrad_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=141µA
I_end=167µA

Every second bond zupfed...

Attachment 1: cal119_goodstrips_apv4.png  119 kB  | Hide | Hide all | Show all
cal119_goodstrips_apv4.png
Attachment 2: cal119_goodstrips_apv5.png  119 kB  | Hide | Hide all | Show all
cal119_goodstrips_apv5.png
Attachment 3: run119_all_hits_apv4.png  120 kB  | Show | Hide all | Show all
Attachment 4: run119_all_hits_apv5.png  121 kB  | Hide | Hide all | Show all
run119_all_hits_apv5.png
Attachment 5: cal119_pednoise_apv4.png  121 kB  | Show | Hide all | Show all
Attachment 6: cal119_pednoise_apv5.png  121 kB  | Hide | Hide all | Show all
cal119_pednoise_apv5.png