Message ID: 146     Entry time: Thu May 19 09:44:39 2011
Author: Manfred Valentan 
Project: Micron Baby 
Subject: DUT3, source run, irrad, postzupf 
Run Number: run118 
Events: 100k 
StartTime: 19.05.2011 09:07:33 
EndTime: 19.05.2011 09:27:21 

DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/postzupf/micronbaby_multi6_irrad_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=18.0µA
I_end=22.6µA

Every second bond zupfed

Attachment 1: cal118_goodstrips_apv4.png  119 kB  | Hide | Hide all | Show all
cal118_goodstrips_apv4.png
Attachment 2: cal118_goodstrips_apv5.png  119 kB  | Show | Hide all | Show all
Attachment 3: run118_all_hits_apv4.png  120 kB  | Hide | Hide all | Show all
run118_all_hits_apv4.png
Attachment 4: run118_all_hits_apv5.png  121 kB  | Hide | Hide all | Show all
run118_all_hits_apv5.png
Attachment 5: cal118_pednoise_apv4.png  117 kB  | Hide | Hide all | Show all
cal118_pednoise_apv4.png
Attachment 6: cal118_pednoise_apv5.png  119 kB  | Show | Hide all | Show all