Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS September/October 2010  Not logged in ELOG logo
Message ID: 132     Entry time: Tue May 17 18:33:07 2011
Author: Manfred Valentan 
Project: Micron Baby 
Subject: GEW8, source run, unirrad, prezupf 
Run Number: run111 
Events: 100k 
StartTime: 17.05.2011 18:01:41 
EndTime: 17.05.2011 18:23:24 

NOT usable as DUT

GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=2.2µA

n-side: most of zones 1 and 3 unusable

Attachment 1: run111_all_hits_apv4.png  120 kB  Uploaded Tue May 17 19:35:57 2011  | Hide | Hide all | Show all
run111_all_hits_apv4.png
Attachment 2: run111_all_hits_apv5.png  119 kB  Uploaded Tue May 17 19:36:06 2011  | Hide | Hide all | Show all
run111_all_hits_apv5.png
Attachment 3: cal111_pednoise_apv4.png  117 kB  Uploaded Tue May 17 19:36:17 2011  | Hide | Hide all | Show all
cal111_pednoise_apv4.png
Attachment 4: cal111_pednoise_apv5.png  118 kB  Uploaded Tue May 17 19:36:27 2011  | Show | Hide all | Show all
ELOG V3.1.5-fc6679b