Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in 2023, Page 9 of 26
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
RD50-MPW3
TJ-Monopix2
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
508 Entries
Goto page
Previous
1
,
2
,
3
...
8
, 9,
10
...
24
,
25
,
26
Next
ID
Date
Author
Subject
Run Number
DUT
Wafer
HV
Fluence
Resistivity
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Text
308
Tue Jul 11 16:05:13 2023
tb-crew
first proper tests
RD50-MPW3
unknown
71
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
Reduced HV
309
Tue Jul 11 16:19:54 2023
tb-crew
first proper tests
1164
RD50-MPW3
unknown
71
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
11.07.2023 16:00:41
11.07.2023 16:15:24
14
automatic log for run 1164
Comment:
Reduced HV
485
Sat Jul 15 19:30:58 2023
tb-crew
cooled unirradiated
1325
RD50-MPW3
unknown
70
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 19:11:26
15.07.2023 19:26:14
14
automatic log for run 1325
Comment:
bias scan 10v steps
310
Tue Jul 11 16:20:23 2023
tb-crew
first proper tests
RD50-MPW3
unknown
61
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
Reduced HV
311
Tue Jul 11 16:33:26 2023
tb-crew
first proper tests
1165
RD50-MPW3
unknown
61
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
11.07.2023 16:18:12
11.07.2023 16:28:56
10
automatic log for run 1165
Comment:
Reduced HV
486
Sat Jul 15 19:48:08 2023
tb-crew
cooled unirradiated
RD50-MPW3
unknown
60
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
adjusting stage, we don't hit centered
ATTENTION: adjustment (also) happened between
run 1327 and 1326
487
Sat Jul 15 19:48:53 2023
tb-crew
cooled unirradiated
1326
RD50-MPW3
unknown
60
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 19:28:42
15.07.2023 19:44:09
15
automatic log for run 1326
Comment:
bias scan in 10v steps
312
Tue Jul 11 16:34:30 2023
tb-crew
first proper tests
RD50-MPW3
unknown
51
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
Reduced HV
313
Tue Jul 11 16:53:07 2023
tb-crew
first proper tests
1167
RD50-MPW3
unknown
51
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
11.07.2023 16:36:17
11.07.2023 16:48:36
12
automatic log for run 1167
Comment:
488
Sat Jul 15 20:00:57 2023
tb-crew
cooled unirradiated
1327
RD50-MPW3
unknown
50
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 19:45:59
15.07.2023 19:56:13
10
automatic log for run 1327
Comment:
bias scan in 10v steps
314
Tue Jul 11 17:33:14 2023
tb-crew
first proper tests
1168
RD50-MPW3
unknown
41
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
11.07.2023 16:51:05
11.07.2023 17:28:44
37
automatic log for run 1168
Comment:
489
Sat Jul 15 20:13:25 2023
tb-crew
cooled unirradiated
1328
RD50-MPW3
unknown
40
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 20:00:04
15.07.2023 20:08:41
8
automatic log for run 1328
Comment:
bias scan in 10v steps
315
Tue Jul 11 17:33:59 2023
tb-crew
first proper tests
RD50-MPW3
unknown
31
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
Decrease HV
316
Tue Jul 11 17:49:09 2023
tb-crew
first proper tests
1169
RD50-MPW3
unknown
31
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
11.07.2023 17:30:54
11.07.2023 17:44:39
13
automatic log for run 1169
Comment:
Decrease HV
490
Sat Jul 15 20:25:37 2023
tb-crew
cooled unirradiated
1329
RD50-MPW3
unknown
30
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 20:10:27
15.07.2023 20:20:53
10
automatic log for run 1329
Comment:
bias scan in 10v steps
317
Tue Jul 11 18:01:03 2023
tb-crew
first proper tests
1170
RD50-MPW3
unknown
21
unirradiated
1.9K
4.2
Low Flux Low
electron
Unknown
11.07.2023 17:47:11
11.07.2023 17:56:33
9
automatic log for run 1170
Comment:
Decrease HV
491
Sat Jul 15 20:37:54 2023
tb-crew
cooled unirradiated
1330
RD50-MPW3
unknown
20
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 20:22:49
15.07.2023 20:33:10
10
automatic log for run 1330
Comment:
bias scan in 10v steps
442
Sat Jul 15 10:22:32 2023
tb-crew
irradiated
RD50-MPW3
unknown
105
1e14
1.9K
4.2
Low Flux Low
electron
Good
changed bias, is short before breakdown now
443
Sat Jul 15 10:34:24 2023
tb-crew
irradiated
1291
RD50-MPW3
unknown
105
1e14
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 10:19:01
15.07.2023 10:29:42
10
automatic log for run 1291
Comment:
444
Sat Jul 15 10:39:00 2023
tb-crew
irradiated
1292
RD50-MPW3
unknown
105
1e14
1.9K
4.2
Low Flux Low
electron
Good
15.07.2023 10:30:16
15.07.2023 10:34:17
4
automatic log for run 1292
Comment:
thr = 1.1V, theres a noisy pixel
Goto page
Previous
1
,
2
,
3
...
8
, 9,
10
...
24
,
25
,
26
Next
ELOG V3.1.5-fc6679b