Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2023, Page 9 of 26  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Wafer HVdown Fluence Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min
  308   Tue Jul 11 16:05:13 2023 tb-crewfirst proper tests RD50-MPW3unknown71unirradiated1.9K4.2Low Flux LowelectronUnknown   
Reduced HV
  309   Tue Jul 11 16:19:54 2023 tb-crewfirst proper tests1164RD50-MPW3unknown71unirradiated1.9K4.2Low Flux LowelectronUnknown11.07.2023 16:00:4111.07.2023 16:15:2414
automatic log for run 1164
Comment:
Reduced HV
  485   Sat Jul 15 19:30:58 2023 tb-crewcooled unirradiated 1325RD50-MPW3unknown70unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 19:11:2615.07.2023 19:26:1414
automatic log for run 1325
Comment:
bias scan 10v steps
  310   Tue Jul 11 16:20:23 2023 tb-crewfirst proper tests RD50-MPW3unknown61unirradiated1.9K4.2Low Flux LowelectronUnknown   
Reduced HV
  311   Tue Jul 11 16:33:26 2023 tb-crewfirst proper tests1165RD50-MPW3unknown61unirradiated1.9K4.2Low Flux LowelectronUnknown11.07.2023 16:18:1211.07.2023 16:28:5610
automatic log for run 1165
Comment:
Reduced HV
  486   Sat Jul 15 19:48:08 2023 tb-crewcooled unirradiated  RD50-MPW3unknown60unirradiated1.9K4.2Low Flux LowelectronGood   
adjusting stage, we don't hit centered
ATTENTION: adjustment (also) happened between run 1327 and 1326
  487   Sat Jul 15 19:48:53 2023 tb-crewcooled unirradiated 1326RD50-MPW3unknown60unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 19:28:4215.07.2023 19:44:0915
automatic log for run 1326
Comment:
bias scan in 10v steps
  312   Tue Jul 11 16:34:30 2023 tb-crewfirst proper tests RD50-MPW3unknown51unirradiated1.9K4.2Low Flux LowelectronUnknown   
Reduced HV
  313   Tue Jul 11 16:53:07 2023 tb-crewfirst proper tests1167RD50-MPW3unknown51unirradiated1.9K4.2Low Flux LowelectronUnknown11.07.2023 16:36:1711.07.2023 16:48:3612
automatic log for run 1167
Comment:
  488   Sat Jul 15 20:00:57 2023 tb-crewcooled unirradiated 1327RD50-MPW3unknown50unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 19:45:5915.07.2023 19:56:1310
automatic log for run 1327
Comment:
bias scan in 10v steps
  314   Tue Jul 11 17:33:14 2023 tb-crewfirst proper tests1168RD50-MPW3unknown41unirradiated1.9K4.2Low Flux LowelectronUnknown11.07.2023 16:51:0511.07.2023 17:28:4437
automatic log for run 1168
Comment:
  489   Sat Jul 15 20:13:25 2023 tb-crewcooled unirradiated 1328RD50-MPW3unknown40unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 20:00:0415.07.2023 20:08:418
automatic log for run 1328
Comment:
bias scan in 10v steps
  315   Tue Jul 11 17:33:59 2023 tb-crewfirst proper tests RD50-MPW3unknown31unirradiated1.9K4.2Low Flux LowelectronUnknown   
Decrease HV
  316   Tue Jul 11 17:49:09 2023 tb-crewfirst proper tests1169RD50-MPW3unknown31unirradiated1.9K4.2Low Flux LowelectronUnknown11.07.2023 17:30:5411.07.2023 17:44:3913
automatic log for run 1169
Comment:
Decrease HV
  490   Sat Jul 15 20:25:37 2023 tb-crewcooled unirradiated 1329RD50-MPW3unknown30unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 20:10:2715.07.2023 20:20:5310
automatic log for run 1329
Comment:
bias scan in 10v steps
  317   Tue Jul 11 18:01:03 2023 tb-crewfirst proper tests1170RD50-MPW3unknown21unirradiated1.9K4.2Low Flux LowelectronUnknown11.07.2023 17:47:1111.07.2023 17:56:339
automatic log for run 1170
Comment:
Decrease HV
  491   Sat Jul 15 20:37:54 2023 tb-crewcooled unirradiated 1330RD50-MPW3unknown20unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 20:22:4915.07.2023 20:33:1010
automatic log for run 1330
Comment:
bias scan in 10v steps
  442   Sat Jul 15 10:22:32 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
changed bias, is short before breakdown now
  443   Sat Jul 15 10:34:24 2023 tb-crewirradiated1291RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:19:0115.07.2023 10:29:4210
automatic log for run 1291
Comment:
  444   Sat Jul 15 10:39:00 2023 tb-crewirradiated1292RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:30:1615.07.2023 10:34:174
automatic log for run 1292
Comment:
thr = 1.1V, theres a noisy pixel
ELOG V3.1.5-fc6679b