Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in 2023, Page 6 of 26
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
RD50-MPW3
TJ-Monopix2
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
508 Entries
Goto page
Previous
1
,
2
,
3
...
5
, 6,
7
...
24
,
25
,
26
Next
ID
Date
Author
Subject
Run Number
DUT
Wafer
HV
Fluence
Resistivity
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Text
408
Fri Jul 14 11:20:46 2023
tb-crew
threshold optimization
1267
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 11:12:12
14.07.2023 11:16:06
3
automatic log for run 1267
Comment:
thr 1.08V
407
Fri Jul 14 11:09:27 2023
tb-crew
threshold optimization
1266
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 11:03:21
14.07.2023 11:04:48
1
automatic log for run 1266
Comment:
masked 15 more rows, thr 1.05V
406
Fri Jul 14 11:04:16 2023
tb-crew
threshold optimization
1265
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:52:34
14.07.2023 10:59:37
7
automatic log for run 1265
Comment:
thr 1.1V seems to be good
405
Fri Jul 14 10:55:25 2023
tb-crew
proper data taking
1264
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:49:38
14.07.2023 10:50:45
1
automatic log for run 1264
Comment:
thr 1.1 seems to be not in noise
404
Fri Jul 14 10:50:32 2023
tb-crew
proper data taking
1263
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:45:31
14.07.2023 10:45:52
0
automatic log for run 1263
Comment:
403
Fri Jul 14 10:48:46 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
thr 1.08V is noise
402
Fri Jul 14 10:48:12 2023
tb-crew
proper data taking
1262
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:43:15
14.07.2023 10:43:33
0
automatic log for run 1262
Comment:
401
Fri Jul 14 10:46:29 2023
tb-crew
proper data taking
1261
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:40:11
14.07.2023 10:41:50
1
automatic log for run 1261
Comment:
400
Fri Jul 14 10:37:04 2023
tb-crew
proper data taking
1258
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:29:41
14.07.2023 10:32:24
2
automatic log for run 1258
Comment:
reduced thr to 1.12
399
Fri Jul 14 10:32:49 2023
tb-crew
proper data taking
1257
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:25:41
14.07.2023 10:28:10
2
automatic log for run 1257
Comment:
reduced thr to 1.15 and deactivated rows,
398
Fri Jul 14 10:29:10 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
4.8
Low Flux Low
electron
Good
reduced thr to 1.15 and deactivated rows,
trying to go as low with thr as possible
without noise for efficiency
397
Fri Jul 14 10:21:12 2023
tb-crew
proper data taking
1256
RD50-MPW3
unknown
91
unirradiated
1.9K
4.8
Low Flux Low
electron
Good
14.07.2023 10:09:47
14.07.2023 10:16:33
6
automatic log for run 1256
Comment:
396
Fri Jul 14 10:14:05 2023
tb-crew
proper data taking
1255
RD50-MPW3
unknown
91
unirradiated
1.9K
5.2
Low Flux Low
electron
Good
14.07.2023 10:03:00
14.07.2023 10:09:25
6
automatic log for run 1255
Comment:
395
Fri Jul 14 10:07:12 2023
tb-crew
proper data taking
1254
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Good
14.07.2023 09:41:18
14.07.2023 10:02:33
21
automatic log for run 1254
Comment:
394
Fri Jul 14 09:47:03 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Good
Petra is most likely causing our efficiency
drops in time, testing now if timeshift is
rate dependent (see energy)
393
Fri Jul 14 09:45:00 2023
tb-crew
proper data taking
1253
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 09:20:02
14.07.2023 09:40:20
20
automatic log for run 1253
Comment:
392
Fri Jul 14 09:06:48 2023
tb-crew
proper data taking
1252
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 00:01:19
14.07.2023 09:02:09
540
automatic log for run 1252
Comment:
391
Thu Jul 13 22:03:55 2023
tb-crew
proper data taking
1251
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
13.07.2023 20:58:16
13.07.2023 21:59:17
61
automatic log for run 1251
Comment:
390
Thu Jul 13 21:02:45 2023
tb-crew
proper data taking
1250
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
13.07.2023 18:18:07
13.07.2023 20:58:08
160
automatic log for run 1250
Comment:
389
Thu Jul 13 18:26:34 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
disconnected piggy
Goto page
Previous
1
,
2
,
3
...
5
, 6,
7
...
24
,
25
,
26
Next
ELOG V3.1.5-fc6679b