Entry  Thu Jul 13 17:35:31 2023, tb-crew, proper data taking, , RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, , ,  
moving telescopes back closer together as "gbl" tracking seems to have a problem with the new geometry (or we are underestimating material budget of our DUT)
Entry  Thu Jul 13 18:12:26 2023, tb-crew, proper data taking, 1249, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 13.07.2023 17:51:45, 13.07.2023 18:07:49, 16 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1249
Mit TLU-timewindow [-115us, +115us] Efficiency von ~52%
Entry  Thu Jul 13 18:26:34 2023, tb-crew, proper data taking, , RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, , ,  
disconnected piggy
Entry  Thu Jul 13 21:02:45 2023, tb-crew, proper data taking, 1250, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 13.07.2023 18:18:07, 13.07.2023 20:58:08, 160 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1250
Comment:
Entry  Thu Jul 13 22:03:55 2023, tb-crew, proper data taking, 1251, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 13.07.2023 20:58:16, 13.07.2023 21:59:17, 61 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1251
Comment:
Entry  Fri Jul 14 09:06:48 2023, tb-crew, proper data taking, 1252, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 00:01:19, 14.07.2023 09:02:09, 540 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1252
Comment:
Entry  Fri Jul 14 09:45:00 2023, tb-crew, proper data taking, 1253, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 09:20:02, 14.07.2023 09:40:20, 20 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1253
Comment:
Entry  Fri Jul 14 09:47:03 2023, tb-crew, proper data taking, , RD50-MPW3, unknown, 91, unirradiated, 1.9K, 5.6, Low Flux Low, electron, Good, , ,  
Petra is most likely causing our efficiency drops in time, testing now if timeshift is rate dependent (see energy)
Entry  Fri Jul 14 10:07:12 2023, tb-crew, proper data taking, 1254, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 5.6, Low Flux Low, electron, Good, 14.07.2023 09:41:18, 14.07.2023 10:02:33, 21 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1254
Comment:
Entry  Fri Jul 14 10:14:05 2023, tb-crew, proper data taking, 1255, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 5.2, Low Flux Low, electron, Good, 14.07.2023 10:03:00, 14.07.2023 10:09:25, 6 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1255
Comment:
Entry  Fri Jul 14 10:21:12 2023, tb-crew, proper data taking, 1256, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.8, Low Flux Low, electron, Good, 14.07.2023 10:09:47, 14.07.2023 10:16:33, 6 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1256
Comment:
Entry  Fri Jul 14 10:29:10 2023, tb-crew, proper data taking, , RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.8, Low Flux Low, electron, Good, , ,  
reduced thr to 1.15 and deactivated rows, trying to go as low with thr as possible without noise for efficiency
Entry  Fri Jul 14 10:32:49 2023, tb-crew, proper data taking, 1257, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 10:25:41, 14.07.2023 10:28:10, 2 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1257
Comment:
reduced thr to 1.15 and deactivated rows, trying to go as low with thr as possible without noise for efficiency
Entry  Fri Jul 14 10:37:04 2023, tb-crew, proper data taking, 1258, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 10:29:41, 14.07.2023 10:32:24, 2 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1258
Comment:
reduced thr to 1.12
Entry  Fri Jul 14 10:46:29 2023, tb-crew, proper data taking, 1261, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 10:40:11, 14.07.2023 10:41:50, 1 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1261
Comment:
Entry  Fri Jul 14 10:48:12 2023, tb-crew, proper data taking, 1262, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 10:43:15, 14.07.2023 10:43:33, 0 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1262
Comment:
Entry  Fri Jul 14 10:48:46 2023, tb-crew, proper data taking, , RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, , ,  
thr 1.08V is noise
Entry  Fri Jul 14 10:50:32 2023, tb-crew, proper data taking, 1263, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 10:45:31, 14.07.2023 10:45:52, 0 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1263
Comment:
Entry  Fri Jul 14 10:55:25 2023, tb-crew, proper data taking, 1264, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 10:49:38, 14.07.2023 10:50:45, 1 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1264
Comment:
thr 1.1 seems to be not in noise
Entry  Fri Jul 14 11:04:16 2023, tb-crew, threshold optimization, 1265, RD50-MPW3, unknown, 91, unirradiated, 1.9K, 4.2, Low Flux Low, electron, Good, 14.07.2023 10:52:34, 14.07.2023 10:59:37, 7 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg
automatic log for run 1265
Comment:
thr 1.1V seems to be good