Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in 2023, Page 4 of 26
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
RD50-MPW3
TJ-Monopix2
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
508 Entries
Goto page
Previous
1
,
2
,
3
, 4,
5
...
24
,
25
,
26
Next
ID
Date
Author
Subject
Run Number
DUT
Wafer
HV
Fluence
Resistivity
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Text
379
Thu Jul 13 12:53:30 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
moved telescope before run1244
380
Thu Jul 13 13:02:36 2023
tb-crew
fw testing
1244
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 12:43:55
13.07.2023 12:58:00
14
automatic log for run 1244
Comment:
381
Thu Jul 13 14:44:00 2023
tb-crew
fw testing
1245
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 13:03:59
13.07.2023 14:39:23
95
automatic log for run 1245
Comment:
382
Thu Jul 13 14:49:48 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
masked row 20 -> 30 cause we tripped into
noise over lunch run
383
Thu Jul 13 14:50:55 2023
tb-crew
fw testing
1246
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 14:40:58
13.07.2023 14:46:18
5
automatic log for run 1246
Comment:
384
Thu Jul 13 16:16:14 2023
tb-crew
fw testing
1247
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 14:46:26
13.07.2023 16:11:37
85
automatic log for run 1247
Comment:
385
Thu Jul 13 16:19:11 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
ran into noise again, about to increase thr
386
Thu Jul 13 17:34:27 2023
tb-crew
proper data taking
1248
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
13.07.2023 16:23:51
13.07.2023 17:29:50
65
automatic log for run 1248
Comment:
387
Thu Jul 13 17:35:31 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
moving telescopes back closer together as
"gbl" tracking seems to have a problem with
the new geometry (or we are underestimating
388
Thu Jul 13 18:12:26 2023
tb-crew
proper data taking
1249
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
13.07.2023 17:51:45
13.07.2023 18:07:49
16
automatic log for run 1249
Mit TLU-timewindow [-115us, +115us] Efficiency
von ~52%
389
Thu Jul 13 18:26:34 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
disconnected piggy
390
Thu Jul 13 21:02:45 2023
tb-crew
proper data taking
1250
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
13.07.2023 18:18:07
13.07.2023 20:58:08
160
automatic log for run 1250
Comment:
391
Thu Jul 13 22:03:55 2023
tb-crew
proper data taking
1251
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
13.07.2023 20:58:16
13.07.2023 21:59:17
61
automatic log for run 1251
Comment:
392
Fri Jul 14 09:06:48 2023
tb-crew
proper data taking
1252
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 00:01:19
14.07.2023 09:02:09
540
automatic log for run 1252
Comment:
393
Fri Jul 14 09:45:00 2023
tb-crew
proper data taking
1253
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 09:20:02
14.07.2023 09:40:20
20
automatic log for run 1253
Comment:
394
Fri Jul 14 09:47:03 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Good
Petra is most likely causing our efficiency
drops in time, testing now if timeshift is
rate dependent (see energy)
395
Fri Jul 14 10:07:12 2023
tb-crew
proper data taking
1254
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Good
14.07.2023 09:41:18
14.07.2023 10:02:33
21
automatic log for run 1254
Comment:
396
Fri Jul 14 10:14:05 2023
tb-crew
proper data taking
1255
RD50-MPW3
unknown
91
unirradiated
1.9K
5.2
Low Flux Low
electron
Good
14.07.2023 10:03:00
14.07.2023 10:09:25
6
automatic log for run 1255
Comment:
397
Fri Jul 14 10:21:12 2023
tb-crew
proper data taking
1256
RD50-MPW3
unknown
91
unirradiated
1.9K
4.8
Low Flux Low
electron
Good
14.07.2023 10:09:47
14.07.2023 10:16:33
6
automatic log for run 1256
Comment:
398
Fri Jul 14 10:29:10 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
4.8
Low Flux Low
electron
Good
reduced thr to 1.15 and deactivated rows,
trying to go as low with thr as possible
without noise for efficiency