Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in 2023, Page 4 of 26
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
RD50-MPW3
TJ-Monopix2
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
508 Entries
Goto page
Previous
1
,
2
,
3
, 4,
5
...
24
,
25
,
26
Next
ID
Date
Author
Subject
Run Number
DUT
Wafer
HV
Fluence
Resistivity
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Text
367
Thu Jul 13 10:23:24 2023
tb-crew
fw testing
1232
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 10:18:26
13.07.2023 10:18:48
0
automatic log for run 1232
Comment:
368
Thu Jul 13 10:25:47 2023
tb-crew
fw testing
1233
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 10:19:35
13.07.2023 10:21:11
1
automatic log for run 1233
Comment:
369
Thu Jul 13 10:26:36 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
having problems with UDP data format, debugging
370
Thu Jul 13 10:39:26 2023
tb-crew
fw testing
1234
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 10:30:27
13.07.2023 10:34:50
4
automatic log for run 1234
Comment:
371
Thu Jul 13 10:46:58 2023
tb-crew
fw testing
1235
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 10:41:38
13.07.2023 10:42:22
0
automatic log for run 1235
Comment:
372
Thu Jul 13 11:05:25 2023
tb-crew
fw testing
1236
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 10:58:22
13.07.2023 11:00:49
2
automatic log for run 1236
Comment:
373
Thu Jul 13 11:30:57 2023
tb-crew
fw testing
1237
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 11:20:57
13.07.2023 11:26:21
5
automatic log for run 1237
Comment:
374
Thu Jul 13 12:01:05 2023
tb-crew
fw testing
1238
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 11:36:24
13.07.2023 11:56:29
20
automatic log for run 1238
Comment:
375
Thu Jul 13 12:08:15 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
jumper was set wrong, messed up UDP packs
376
Thu Jul 13 12:10:28 2023
tb-crew
fw testing
1242
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 12:04:04
13.07.2023 12:05:52
1
automatic log for run 1242
Comment:
377
Thu Jul 13 12:23:00 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
1e14
1.9K
5.6
Low Flux Low
electron
Unknown
changed FW LSB and MSB switched
Raw Files befor might be incompatible with
EventConverter
378
Thu Jul 13 12:42:56 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
irradiated chip logged before actually not
working
379
Thu Jul 13 12:53:30 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
moved telescope before run1244
380
Thu Jul 13 13:02:36 2023
tb-crew
fw testing
1244
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 12:43:55
13.07.2023 12:58:00
14
automatic log for run 1244
Comment:
381
Thu Jul 13 14:44:00 2023
tb-crew
fw testing
1245
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 13:03:59
13.07.2023 14:39:23
95
automatic log for run 1245
Comment:
382
Thu Jul 13 14:49:48 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
masked row 20 -> 30 cause we tripped into
noise over lunch run
383
Thu Jul 13 14:50:55 2023
tb-crew
fw testing
1246
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 14:40:58
13.07.2023 14:46:18
5
automatic log for run 1246
Comment:
384
Thu Jul 13 16:16:14 2023
tb-crew
fw testing
1247
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
13.07.2023 14:46:26
13.07.2023 16:11:37
85
automatic log for run 1247
Comment:
385
Thu Jul 13 16:19:11 2023
tb-crew
fw testing
RD50-MPW3
unknown
91
unirradiated
1.9K
5.6
Low Flux Low
electron
Unknown
ran into noise again, about to increase thr
386
Thu Jul 13 17:34:27 2023
tb-crew
proper data taking
1248
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
13.07.2023 16:23:51
13.07.2023 17:29:50
65
automatic log for run 1248
Comment:
Goto page