Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2023, Page 25 of 26  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Wafer HV Fluencedown Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min
  435   Sat Jul 15 10:02:11 2023 tb-crewirradiated1287RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood15.07.2023 09:22:0615.07.2023 09:57:2835
automatic log for run 1287
Comment:
thr 1.15V, -0.6 deg C -> lil bit of noise
  436   Sat Jul 15 10:02:57 2023 tb-crewirradiated1288RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood15.07.2023 09:58:1115.07.2023 09:58:140
automatic log for run 1288
Comment:
thr 1.1V, -0.5 deg C
  437   Sat Jul 15 10:03:28 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
that was noise
  438   Sat Jul 15 10:04:38 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
masking all rows below row 50
  439   Sat Jul 15 10:06:15 2023 tb-crewirradiated1289RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood15.07.2023 10:00:5215.07.2023 10:01:320
automatic log for run 1289
Comment:
thr 1.12V, -0.5 deg C, only rows 63 -> 50 active
  440   Sat Jul 15 10:06:28 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
there is a noisy pixel
  441   Sat Jul 15 10:14:43 2023 tb-crewirradiated1290RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood15.07.2023 10:04:0415.07.2023 10:10:005
automatic log for run 1290
Comment:
masked pixel 52:42, looks better now
  442   Sat Jul 15 10:22:32 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
changed bias, is short before breakdown now
  443   Sat Jul 15 10:34:24 2023 tb-crewirradiated1291RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:19:0115.07.2023 10:29:4210
automatic log for run 1291
Comment:
  444   Sat Jul 15 10:39:00 2023 tb-crewirradiated1292RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:30:1615.07.2023 10:34:174
automatic log for run 1292
Comment:
thr = 1.1V, theres a noisy pixel
  445   Sat Jul 15 10:40:09 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
pixel 57:30 is noisy, masking it
  446   Sat Jul 15 10:51:31 2023 tb-crewirradiated1293RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:36:4315.07.2023 10:46:4910
automatic log for run 1293
Comment:
this run might be used for analysis of efficiency of irradiated sensor
lowest threshold, highest bias
  447   Sat Jul 15 10:52:59 2023 tb-crewirradiated1294RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:48:0715.07.2023 10:48:160
automatic log for run 1294
Comment:
set vnfb to 0
  448   Sat Jul 15 10:53:49 2023 tb-crewirradiated1295RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:49:0315.07.2023 10:49:070
automatic log for run 1295
Comment:
set vnfb to 0
  449   Sat Jul 15 11:13:50 2023 tb-crewirradiated1296RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:50:1415.07.2023 11:09:0818
automatic log for run 1296
Comment:
set vnfb to 0, thr at 1.15V
  450   Sat Jul 15 11:15:22 2023 tb-crewirradiated1297RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 11:10:0715.07.2023 11:10:390
automatic log for run 1297
Comment:
set vnfb to 63, thr at 1.15V,NOISY
  451   Sat Jul 15 11:18:48 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
masked 2 more pixel
  452   Sat Jul 15 11:19:48 2023 tb-crewirradiated1298RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 11:14:5215.07.2023 11:15:050
automatic log for run 1298
Comment:
vnfb = 63, thr = 1.15V
  453   Sat Jul 15 11:21:28 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
problems with noisy pixels now, masked 56:30
  454   Sat Jul 15 11:23:46 2023 tb-crewirradiated1299RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 11:17:2215.07.2023 11:19:041
automatic log for run 1299
Comment:
vnfb = 63, thr = 1.15V, noise or too much data, lost UDP packages
ELOG V3.1.5-fc6679b