Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2023, Page 24 of 26  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Wafer HV Fluencedown Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Text Attachments
  415   Fri Jul 14 13:57:18 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   that was noise   
  416   Fri Jul 14 13:59:10 2023 tb-crewirradiated1273RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:53:5814.07.2023 13:54:300automatic log for run 1273
Comment:
thr 1.4V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  417   Fri Jul 14 14:05:27 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   that was overkill, thr 1.3V it is   
  418   Fri Jul 14 14:33:52 2023 tb-crewirradiated1274RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:55:4914.07.2023 14:29:1333automatic log for run 1274
Comment:
thr 1.3V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  419   Fri Jul 14 14:51:11 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   change geometry btw due to montage off cooling
setup
  
  420   Fri Jul 14 15:50:55 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   installed cooling setup   
  421   Fri Jul 14 15:52:51 2023 tb-crewirradiated1275RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:45:3914.07.2023 15:48:112automatic log for run 1275
Comment:
finding threshold: currently
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  422   Fri Jul 14 15:53:40 2023 tb-crewirradiated1276RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:48:5414.07.2023 15:49:000automatic log for run 1276
Comment:
finding threshold: currently
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  423   Fri Jul 14 15:54:43 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   thr 1.20V is noise   
  424   Fri Jul 14 15:57:53 2023 tb-crewirradiated1277RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:50:2114.07.2023 15:53:132automatic log for run 1277
Comment:
thr 1.25V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  425   Fri Jul 14 16:22:32 2023 tb-crewirradiated1278RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:59:1514.07.2023 16:17:5218automatic log for run 1278
Comment:
thr 1.25V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  426   Fri Jul 14 16:25:20 2023 tb-crewirradiated1279RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:18:3114.07.2023 16:20:392automatic log for run 1279
Comment:
thr 1.225V,  -8.6 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  427   Fri Jul 14 16:26:16 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   thr 1.225V,  -8.6 deg C, was running in noise,
deactivated lower 30 rows
  
  428   Fri Jul 14 16:45:29 2023 tb-crewirradiated1280RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:21:4714.07.2023 16:40:4919automatic log for run 1280
Comment:
thr 1.225V,  -8.6 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  429   Fri Jul 14 17:32:50 2023 tb-crewirradiated1281RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:41:4814.07.2023 17:28:1046automatic log for run 1281
Comment:
thr 1.2V,  -1 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  430   Fri Jul 14 17:50:57 2023 tb-crewirradiated1282RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 17:29:3114.07.2023 17:46:1716automatic log for run 1282
Comment:
thr 1.17V,  -0.6 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  431   Fri Jul 14 17:55:30 2023 tb-crewirradiated1283RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 17:49:3714.07.2023 17:50:491automatic log for run 1283
Comment:
thr 1.15V,  -0.6 deg C -> lil bit of noise
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  432   Fri Jul 14 21:00:23 2023 tb-crewirradiated1284RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 17:53:5914.07.2023 20:55:42181automatic log for run 1284
Comment:
thr 1.15V,  -0.6 deg C -> lil bit of noise
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  433   Sat Jul 15 00:46:44 2023 tb-crewirradiated1285RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 21:06:2615.07.2023 00:42:03215automatic log for run 1285
Comment:
thr 1.15V,  -0.6 deg C -> lil bit of noise
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  434   Sat Jul 15 09:26:35 2023 tb-crewirradiated1286RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood15.07.2023 00:42:1615.07.2023 09:21:52519automatic log for run 1286
Comment:
thr 1.15V,  -0.6 deg C -> lil bit of noise
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
ELOG V3.1.5-fc6679b