ID Date Author Subject Run Number DUT Wafer HV Fluence Resistivity Beam Energydown Rate Setting Particle Type Data t-Start t-Stop Duration_min
  467   Sat Jul 15 15:09:08 2023 tb-crewcooled unirradiated  RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood   
thr = 1.09V, vnfb = 0; encountered noisy pixel
  468   Sat Jul 15 15:22:23 2023 tb-crewcooled unirradiated 1308RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 15:07:1115.07.2023 15:17:4010
automatic log for run 1308
Comment:
thr = 1.09V, vnfb = 0; encountered noisy pixel
  469   Sat Jul 15 15:47:47 2023 tb-crewcooled unirradiated 1309RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 15:32:3515.07.2023 15:43:0310
automatic log for run 1309
Comment:
switched to no freeze mode
  470   Sat Jul 15 15:51:53 2023 tb-crewcooled unirradiated 1310RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 15:44:3615.07.2023 15:47:102
automatic log for run 1310
Comment:
switched to no freeze mode
  471   Sat Jul 15 16:19:49 2023 tb-crewcooled unirradiated 1311RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 15:49:2815.07.2023 16:15:0625
automatic log for run 1311
Comment:
no freeze mode
  472   Sat Jul 15 16:21:46 2023 tb-crewcooled unirradiated 1312RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 16:15:1715.07.2023 16:17:031
automatic log for run 1312
Comment:
no freeze mode
  479   Sat Jul 15 17:43:49 2023 tb-crewcooled unirradiated 1319RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 17:15:3815.07.2023 17:39:0623
automatic log for run 1319
Comment:
4,2 Gev still without freeze mode
  480   Sat Jul 15 18:05:48 2023 tb-crewcooled unirradiated 1320RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 17:48:5415.07.2023 18:01:0412
automatic log for run 1320
Comment:
4,2 Gev still without freeze mode
  481   Sat Jul 15 18:10:38 2023 tb-crewcooled unirradiated 1321RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 18:04:5315.07.2023 18:05:541
automatic log for run 1321
Comment:
freeze mode enabled again
  482   Sat Jul 15 18:24:28 2023 tb-crewcooled unirradiated 1322RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 18:08:0015.07.2023 18:19:4511
automatic log for run 1322
Comment:
freeze mode enabled again
  483   Sat Jul 15 18:38:36 2023 tb-crewcooled unirradiated 1323RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 18:19:5615.07.2023 18:33:5213
automatic log for run 1323
Comment:
freeze mode enabled again
  484   Sat Jul 15 19:01:23 2023 tb-crewcooled unirradiated 1324RD50-MPW3unknown80unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 18:44:1715.07.2023 18:56:3912
automatic log for run 1324
Comment:
bias scan 10v steps
  485   Sat Jul 15 19:30:58 2023 tb-crewcooled unirradiated 1325RD50-MPW3unknown70unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 19:11:2615.07.2023 19:26:1414
automatic log for run 1325
Comment:
bias scan 10v steps
  486   Sat Jul 15 19:48:08 2023 tb-crewcooled unirradiated  RD50-MPW3unknown60unirradiated1.9K4.2Low Flux LowelectronGood   
adjusting stage, we don't hit centered
ATTENTION: adjustment (also) happened between run 1327 and 1326
  487   Sat Jul 15 19:48:53 2023 tb-crewcooled unirradiated 1326RD50-MPW3unknown60unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 19:28:4215.07.2023 19:44:0915
automatic log for run 1326
Comment:
bias scan in 10v steps
  488   Sat Jul 15 20:00:57 2023 tb-crewcooled unirradiated 1327RD50-MPW3unknown50unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 19:45:5915.07.2023 19:56:1310
automatic log for run 1327
Comment:
bias scan in 10v steps
  489   Sat Jul 15 20:13:25 2023 tb-crewcooled unirradiated 1328RD50-MPW3unknown40unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 20:00:0415.07.2023 20:08:418
automatic log for run 1328
Comment:
bias scan in 10v steps
  490   Sat Jul 15 20:25:37 2023 tb-crewcooled unirradiated 1329RD50-MPW3unknown30unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 20:10:2715.07.2023 20:20:5310
automatic log for run 1329
Comment:
bias scan in 10v steps
  491   Sat Jul 15 20:37:54 2023 tb-crewcooled unirradiated 1330RD50-MPW3unknown20unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 20:22:4915.07.2023 20:33:1010
automatic log for run 1330
Comment:
bias scan in 10v steps
  492   Sat Jul 15 20:50:08 2023 tb-crewcooled unirradiated 1331RD50-MPW3unknown10unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 20:35:0115.07.2023 20:45:2310
automatic log for run 1331
Comment:
bias scan in 10v steps
ELOG V3.1.5-fc6679b