  440   Sat Jul 15 10:06:28 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
there is a noisy pixel
  441   Sat Jul 15 10:14:43 2023 tb-crewirradiated1290RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood15.07.2023 10:04:0415.07.2023 10:10:005
automatic log for run 1290
Comment:
masked pixel 52:42, looks better now
  442   Sat Jul 15 10:22:32 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
changed bias, is short before breakdown now
  443   Sat Jul 15 10:34:24 2023 tb-crewirradiated1291RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:19:0115.07.2023 10:29:4210
automatic log for run 1291
Comment:
  444   Sat Jul 15 10:39:00 2023 tb-crewirradiated1292RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:30:1615.07.2023 10:34:174
automatic log for run 1292
Comment:
thr = 1.1V, theres a noisy pixel
  445   Sat Jul 15 10:40:09 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
pixel 57:30 is noisy, masking it
  446   Sat Jul 15 10:51:31 2023 tb-crewirradiated1293RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:36:4315.07.2023 10:46:4910
automatic log for run 1293
Comment:
this run might be used for analysis of efficiency of irradiated sensor
lowest threshold, highest bias
  447   Sat Jul 15 10:52:59 2023 tb-crewirradiated1294RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:48:0715.07.2023 10:48:160
automatic log for run 1294
Comment:
set vnfb to 0
  448   Sat Jul 15 10:53:49 2023 tb-crewirradiated1295RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:49:0315.07.2023 10:49:070
automatic log for run 1295
Comment:
set vnfb to 0
  449   Sat Jul 15 11:13:50 2023 tb-crewirradiated1296RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 10:50:1415.07.2023 11:09:0818
automatic log for run 1296
Comment:
set vnfb to 0, thr at 1.15V
  450   Sat Jul 15 11:15:22 2023 tb-crewirradiated1297RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 11:10:0715.07.2023 11:10:390
automatic log for run 1297
Comment:
set vnfb to 63, thr at 1.15V,NOISY
  451   Sat Jul 15 11:18:48 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
masked 2 more pixel
  452   Sat Jul 15 11:19:48 2023 tb-crewirradiated1298RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 11:14:5215.07.2023 11:15:050
automatic log for run 1298
Comment:
vnfb = 63, thr = 1.15V
  453   Sat Jul 15 11:21:28 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
problems with noisy pixels now, masked 56:30
  454   Sat Jul 15 11:23:46 2023 tb-crewirradiated1299RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood15.07.2023 11:17:2215.07.2023 11:19:041
automatic log for run 1299
Comment:
vnfb = 63, thr = 1.15V, noise or too much data, lost UDP packages
  455   Sat Jul 15 11:27:30 2023 tb-crewirradiated RD50-MPW3unknown1051e141.9K4.2Low Flux LowelectronGood   
installing unirradiated sensor in cooling setup
  456   Sat Jul 15 11:30:08 2023 tb-crewcooled unirradiated  RD50-MPW3unknown105unirradiated1.9K4.2Low Flux LowelectronGood   
half of the matrix active, vnfb back to 18 and thr = 1.1V
  457   Sat Jul 15 11:31:04 2023 tb-crewcooled unirradiated  RD50-MPW3unknown105unirradiated1.9K4.2Low Flux LowelectronGood   
changed telescope geometry
  458   Sat Jul 15 12:25:30 2023 tb-crewcooled unirradiated  RD50-MPW3unknown105unirradiated1.9K4.2Low Flux LowelectronGood   
T = +8 degC atm (falling), HB for pixel 46:10 active
  459   Sat Jul 15 12:25:59 2023 tb-crewcooled unirradiated 1300RD50-MPW3unknown105unirradiated1.9K4.2Low Flux LowelectronGood15.07.2023 12:21:0015.07.2023 12:21:160
automatic log for run 1300
Comment:
T = +8 degC atm (falling), HB for pixel 46:10 active