ID Date Author Subject Run Number DUT Waferdown HV Fluence Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min
  408   Fri Jul 14 11:20:46 2023 tb-crewthreshold optimization1267RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:12:1214.07.2023 11:16:063
automatic log for run 1267
Comment:
thr 1.08V
  409   Fri Jul 14 11:34:57 2023 tb-crewthreshold optimization1268RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:18:1614.07.2023 11:30:1812
automatic log for run 1268
Comment:
now only rows 63 -> 54 active , thr 1.06
  410   Fri Jul 14 11:39:52 2023 tb-crewthreshold optimization1269RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:32:0614.07.2023 11:35:123
automatic log for run 1269
Comment:
thr 1.055, running without beam cause fans examining our setup
is a bit noisy, but not too bad, give it some beam in next run
  411   Fri Jul 14 11:59:54 2023 tb-crewthreshold optimization1270RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:40:2014.07.2023 11:55:1414
automatic log for run 1270
Comment:
thr 1.055
  412   Fri Jul 14 12:57:09 2023 tb-crewthreshold optimization1271RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 11:55:2414.07.2023 12:52:2957
automatic log for run 1271
Comment:
thr 1.055
  413   Fri Jul 14 13:56:09 2023 tb-crewthreshold optimization RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
now really going for Sams irradiated chip
  414   Fri Jul 14 13:57:09 2023 tb-crewirradiated1272RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:52:2414.07.2023 13:52:290
automatic log for run 1272
Comment:
  415   Fri Jul 14 13:57:18 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
that was noise
  416   Fri Jul 14 13:59:10 2023 tb-crewirradiated1273RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:53:5814.07.2023 13:54:300
automatic log for run 1273
Comment:
thr 1.4V
  417   Fri Jul 14 14:05:27 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
that was overkill, thr 1.3V it is
  418   Fri Jul 14 14:33:52 2023 tb-crewirradiated1274RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:55:4914.07.2023 14:29:1333
automatic log for run 1274
Comment:
thr 1.3V
  419   Fri Jul 14 14:51:11 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
change geometry btw due to montage off cooling setup
  420   Fri Jul 14 15:50:55 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
installed cooling setup
  421   Fri Jul 14 15:52:51 2023 tb-crewirradiated1275RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:45:3914.07.2023 15:48:112
automatic log for run 1275
Comment:
finding threshold: currently
  422   Fri Jul 14 15:53:40 2023 tb-crewirradiated1276RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:48:5414.07.2023 15:49:000
automatic log for run 1276
Comment:
finding threshold: currently
  423   Fri Jul 14 15:54:43 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
thr 1.20V is noise
  424   Fri Jul 14 15:57:53 2023 tb-crewirradiated1277RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:50:2114.07.2023 15:53:132
automatic log for run 1277
Comment:
thr 1.25V
  425   Fri Jul 14 16:22:32 2023 tb-crewirradiated1278RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:59:1514.07.2023 16:17:5218
automatic log for run 1278
Comment:
thr 1.25V
  426   Fri Jul 14 16:25:20 2023 tb-crewirradiated1279RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:18:3114.07.2023 16:20:392
automatic log for run 1279
Comment:
thr 1.225V, -8.6 deg C
  427   Fri Jul 14 16:26:16 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   
thr 1.225V, -8.6 deg C, was running in noise, deactivated lower 30 rows
ELOG V3.1.5-fc6679b