Testbeam at DESY in 2023, Page 13 of 26
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
RD50-MPW3
TJ-Monopix2
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
508 Entries
Goto page
Previous
1
,
2
,
3
...
12
, 13,
14
...
24
,
25
,
26
Next
ID
Date
Author
Subject
Run Number
DUT
Wafer
HV
Fluence
Resistivity
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Text
403
Fri Jul 14 10:48:46 2023
tb-crew
proper data taking
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
thr 1.08V is noise
404
Fri Jul 14 10:50:32 2023
tb-crew
proper data taking
1263
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:45:31
14.07.2023 10:45:52
0
automatic log for run 1263
Comment:
405
Fri Jul 14 10:55:25 2023
tb-crew
proper data taking
1264
RD50-MPW3
unknown
91
unirradiated
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 10:49:38
14.07.2023 10:50:45
1
automatic log for run 1264
Comment:
thr 1.1 seems to be not in noise
414
Fri Jul 14 13:57:09 2023
tb-crew
irradiated
1272
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 13:52:24
14.07.2023 13:52:29
0
automatic log for run 1272
Comment:
415
Fri Jul 14 13:57:18 2023
tb-crew
irradiated
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
that was noise
416
Fri Jul 14 13:59:10 2023
tb-crew
irradiated
1273
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 13:53:58
14.07.2023 13:54:30
0
automatic log for run 1273
Comment:
thr 1.4V
417
Fri Jul 14 14:05:27 2023
tb-crew
irradiated
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
that was overkill, thr 1.3V it is
418
Fri Jul 14 14:33:52 2023
tb-crew
irradiated
1274
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 13:55:49
14.07.2023 14:29:13
33
automatic log for run 1274
Comment:
thr 1.3V
419
Fri Jul 14 14:51:11 2023
tb-crew
irradiated
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
change geometry btw due to montage off cooling
setup
420
Fri Jul 14 15:50:55 2023
tb-crew
irradiated
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
installed cooling setup
421
Fri Jul 14 15:52:51 2023
tb-crew
irradiated
1275
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 15:45:39
14.07.2023 15:48:11
2
automatic log for run 1275
Comment:
finding threshold: currently
422
Fri Jul 14 15:53:40 2023
tb-crew
irradiated
1276
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 15:48:54
14.07.2023 15:49:00
0
automatic log for run 1276
Comment:
finding threshold: currently
423
Fri Jul 14 15:54:43 2023
tb-crew
irradiated
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
thr 1.20V is noise
424
Fri Jul 14 15:57:53 2023
tb-crew
irradiated
1277
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 15:50:21
14.07.2023 15:53:13
2
automatic log for run 1277
Comment:
thr 1.25V
425
Fri Jul 14 16:22:32 2023
tb-crew
irradiated
1278
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 15:59:15
14.07.2023 16:17:52
18
automatic log for run 1278
Comment:
thr 1.25V
426
Fri Jul 14 16:25:20 2023
tb-crew
irradiated
1279
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 16:18:31
14.07.2023 16:20:39
2
automatic log for run 1279
Comment:
thr 1.225V, -8.6 deg C
427
Fri Jul 14 16:26:16 2023
tb-crew
irradiated
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
thr 1.225V, -8.6 deg C, was running in noise,
deactivated lower 30 rows
428
Fri Jul 14 16:45:29 2023
tb-crew
irradiated
1280
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 16:21:47
14.07.2023 16:40:49
19
automatic log for run 1280
Comment:
thr 1.225V, -8.6 deg C
429
Fri Jul 14 17:32:50 2023
tb-crew
irradiated
1281
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 16:41:48
14.07.2023 17:28:10
46
automatic log for run 1281
Comment:
thr 1.2V, -1 deg C
430
Fri Jul 14 17:50:57 2023
tb-crew
irradiated
1282
RD50-MPW3
unknown
91
1e14
1.9K
4.2
Low Flux Low
electron
Good
14.07.2023 17:29:31
14.07.2023 17:46:17
16
automatic log for run 1282
Comment:
thr 1.17V, -0.6 deg C
Goto page
Previous
1
,
2
,
3
...
12
, 13,
14
...
24
,
25
,
26
Next
ELOG V3.1.5-fc6679b