ID Date Author Subjectdown Run Number DUT Wafer HV Fluence Resistivity Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Text Attachments
  403   Fri Jul 14 10:48:46 2023 tb-crewproper data taking RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood   thr 1.08V is noise   
  404   Fri Jul 14 10:50:32 2023 tb-crewproper data taking1263RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:45:3114.07.2023 10:45:520automatic log for run 1263
Comment:
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  405   Fri Jul 14 10:55:25 2023 tb-crewproper data taking1264RD50-MPW3unknown91unirradiated1.9K4.2Low Flux LowelectronGood14.07.2023 10:49:3814.07.2023 10:50:451automatic log for run 1264
Comment:
thr 1.1 seems to be not in noise
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  414   Fri Jul 14 13:57:09 2023 tb-crewirradiated1272RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:52:2414.07.2023 13:52:290automatic log for run 1272
Comment:
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  415   Fri Jul 14 13:57:18 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   that was noise   
  416   Fri Jul 14 13:59:10 2023 tb-crewirradiated1273RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:53:5814.07.2023 13:54:300automatic log for run 1273
Comment:
thr 1.4V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  417   Fri Jul 14 14:05:27 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   that was overkill, thr 1.3V it is   
  418   Fri Jul 14 14:33:52 2023 tb-crewirradiated1274RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 13:55:4914.07.2023 14:29:1333automatic log for run 1274
Comment:
thr 1.3V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  419   Fri Jul 14 14:51:11 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   change geometry btw due to montage off cooling
setup
  
  420   Fri Jul 14 15:50:55 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   installed cooling setup   
  421   Fri Jul 14 15:52:51 2023 tb-crewirradiated1275RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:45:3914.07.2023 15:48:112automatic log for run 1275
Comment:
finding threshold: currently
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  422   Fri Jul 14 15:53:40 2023 tb-crewirradiated1276RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:48:5414.07.2023 15:49:000automatic log for run 1276
Comment:
finding threshold: currently
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  423   Fri Jul 14 15:54:43 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   thr 1.20V is noise   
  424   Fri Jul 14 15:57:53 2023 tb-crewirradiated1277RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:50:2114.07.2023 15:53:132automatic log for run 1277
Comment:
thr 1.25V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  425   Fri Jul 14 16:22:32 2023 tb-crewirradiated1278RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 15:59:1514.07.2023 16:17:5218automatic log for run 1278
Comment:
thr 1.25V
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  426   Fri Jul 14 16:25:20 2023 tb-crewirradiated1279RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:18:3114.07.2023 16:20:392automatic log for run 1279
Comment:
thr 1.225V,  -8.6 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  427   Fri Jul 14 16:26:16 2023 tb-crewirradiated RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood   thr 1.225V,  -8.6 deg C, was running in noise,
deactivated lower 30 rows
  
  428   Fri Jul 14 16:45:29 2023 tb-crewirradiated1280RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:21:4714.07.2023 16:40:4919automatic log for run 1280
Comment:
thr 1.225V,  -8.6 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  429   Fri Jul 14 17:32:50 2023 tb-crewirradiated1281RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 16:41:4814.07.2023 17:28:1046automatic log for run 1281
Comment:
thr 1.2V,  -1 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
  430   Fri Jul 14 17:50:57 2023 tb-crewirradiated1282RD50-MPW3unknown911e141.9K4.2Low Flux LowelectronGood14.07.2023 17:29:3114.07.2023 17:46:1716automatic log for run 1282
Comment:
thr 1.17V,  -0.6 deg C
 peary_config.cfgmatrix_config_base.txtmatrix_config_piggy.txteudaq_config.cfg 
ELOG V3.1.5-fc6679b