Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2023  Not logged in ELOG logo
Message ID: 73     Entry time: Wed Jul 5 17:47:44 2023
Author: tb-crew 
Subject: searching correlations 
Run Number: 676 
DUT: RD50-MPW3 
Wafer: unknown 
HV:  
Fluence: unirradiated 
Resistivity: 1.9K 
Beam Energy: 4.2 
Rate Setting:  
Particle Type: electron 
Data: Unknown 
t-Start: 05.07.2023 17:38:24 
t-Stop: 05.07.2023 17:43:33 
Duration_min:
automatic log for run 676
Comment:
moving stage to check for alignment
Attachment 1: peary_config.cfg  1 kB  | Show | Hide all | Show all
Attachment 2: matrix_config_base.txt  32 kB  | Show | Hide all | Show all
Attachment 3: matrix_config_piggy.txt  32 kB  | Show | Hide all | Show all
Attachment 4: eudaq_config.cfg  6 kB  | Hide | Hide all | Show all
[RunControl]
EUDAQ_CTRL_PRODUCER_LAST_START = aida_tlu

[LogCollector.log]

[Producer.aida_tlu]
verbose = 0
confid = 20181002
skipconf = 0

# delay start in ms
delayStart = 0

####################################################
# DUT IN/OUTPUT

# Mask: 0 CONT, 1 SPARE, 2 TRIG, 3 BUSY (1 = driven by TLU, 0 = driven by DUT) 
# EUDET mode: 7
HDMI1_set = 0x7
HDMI2_set = 0x7
HDMI3_set = 0x7
HDMI4_set = 0x7

# same as above for the clock line, 1 = AIDA mode, 2 = FPGA 
HDMI1_clk = 1
HDMI2_clk = 0
HDMI3_clk = 1
HDMI4_clk = 0
LEMOclk = 1   # if input, then also adjust clk.txt

# Activate channels
# Only TLU
#DUTMask = 0x0
# Telescope at HDMI1
#DUTMask = 0x1
# Only FEI4 at HDMI2
#DUTMask = 0x2
# Telescope at HDMI1, FEI4 at HDMI2
#DUTMask = 0x3
#Adenium at HDMI3
#DUTMask = 0x1

#Adenium at HDMI1,  MPW3 at HDMI3, Monopix2 at HDMI4
DUTMask = 0xD

# Define mode: 
# Each DUT channel has two bits: HDMI1=0&1 bit; HDMI2= 2&3bit; ...
# Only the lowest bit is significant:
# AIDA mode for each "1st" LSbit = 1
# EUDET modes incl. DUT clocking out each "1st" LSbit = 0
# e.g. 1st and 2nd channel in EUDET mode: 0xF0
#DUTMaskMode = 0xF0 # 1st and 2nd channel are reading out Trigger ID
# e.g. only 1st in EUDET mode
#DUTMaskMode = 0xFC # 1st is reading out Trigger ID

#!!!!!!!!!!!! Check this !!!!!!!!!!!!!!!
#DUTMaskMode = 0x01 #I think this is AIDA mode for channel 3 and reading out trigger number

#HDMI3 on AIDA with trigger number
DUTMaskMode = 0x11

# "Mixed mode" to ignore a busy line from a DUT
# TLU ignores the telescope busy (at HDMI1)
#DUTIgnoreBusy = 0x1 # yes (default, Mixed mode)
DUTIgnoreBusy = 0x2 #no (EUDET mode)

###################################################
# ONLY AUTOTRIGGER 
#InternalTriggerFreq = 1000

# also set this to 0
trigMaskHi = 0x00000000
trigMaskLo = 0x00000008

# EXTERNAL TRIGGER INPUTs
# Stretch, delay in 6.25ns ticks
in0_STR = 7  # factor to stretch the width of the signal; to get coincidence 
in0_DEL = 0  # factor to delay, e.g. compensate  
in1_STR = 7
in1_DEL = 0
in2_STR = 7
in2_DEL = 0
in3_STR = 7
in3_DEL = 0
in4_STR = 0
in4_DEL = 0
in5_STR = 0
in5_DEL = 0

# DAC INPUT THRESHOLD in V
DACThreshold0 = -0.4  # Was -0.04, but we get amplyfied signal from NIM module
DACThreshold1 = -0.4  # Was -0.04, but we get amplyfied signal from NIM module
DACThreshold2 = -0.20
DACThreshold3 = -0.20
DACThreshold4 = -0.20
DACThreshold5 = -0.20

# PMT Power
PMT1_V = 0.80
PMT2_V = 0.80
PMT3_V = 0.00
PMT4_V = 0.00

# 2 words 32bit: Hi + Lo
# combinations of coincidence are now possible! 

# Coincidence of input 0 to 3 (telescope)
#trigMaskHi = 0x00000000
#trigMaskLo = 0x00008000

# Coincidence of input 0 and 1
trigMaskHi = 0x00000000
trigMaskLo = 0x00000008

# New: Coincidence of any 3 of 4, 4 combinations plus all 4
#trigMaskHi = 0x00000000
#trigMaskLo = 0x0000C880

# EUDAQ2
# Define the data collector to be used by the producer
EUDAQ_DC = dc_tlu



[DataCollector.dc_tlu]
EUDAQ_ID=100
EUDAQ_MN=StdEventMonitor
EUDAQ_DATACOL_SEND_MONITOR_FRACTION=5
EUDAQ_FW = native
EUDAQ_FW_PATTERN = "/media/bellevtx01/TOSHIBA EXT/VTX/data_producer_runs/desy/run$6R_tlu$X"
DISABLE_PRINT = 1

################################### Adenium #####################################
[Producer.altel]
EUDAQ_ID=1
EUDAQ_DC=dc_tel


[DataCollector.dc_tel]
EUDAQ_ID=100
EUDAQ_MN=StdEventMonitor
EUDAQ_DATACOL_SEND_MONITOR_FRACTION=1
EUDAQ_FW = native
EUDAQ_FW_PATTERN = "/media/bellevtx01/TOSHIBA EXT/VTX/data_producer_runs/desy/run$6R_adenium$X"
DISABLE_PRINT = 1

################################### MPW3 #####################################

[Producer.RD50_MPW3]


[DataCollector.mpw3_dc]
# connection to the monitor
EUDAQ_MN = mpw3_mon
EUDAQ_FW = native
EUDAQ_FW_PATTERN = /media/silicon/backup/desy_jul23/run$6R_mpw3$X
EUDAQ_DATACOL_SEND_MONITOR_FRACTION = 500
# config-parameters
DISABLE_PRINT = 1
XILINX_IP = 192.168.201.1
SYNC_MODE = 1

[Monitor.mpw3_mon]
ENABLE_PRINT = 0
ENABLE_STD_PRINT = 0
ENABLE_STD_CONVERTER = 1
FORWARD2GUI = 1

[Producer.elog_mpw3]

# command (shell script) to execute before starting a run
start_cmd = "./copy_configs.sh" 

#files to attach to the Elog entry
files2log = "tmp/peary_config.cfg, tmp/matrix_config_base.txt, tmp/matrix_config_piggy.txt, tmp/eudaq_config.cfg" 



################################################ MPX2 #####################################################


[Producer.monopix2]
# connection to the data collector
EUDAQ_DC = dc_mpx2
ENABLE_BDAQ_RECORD = 1
ENABLE_HITOR = 1
#CHIP_CONFIG_FILE = /home/bellevtx01/vtx/tj-monopix2-daq_mx/tj-monopix2-daq/tjmonopix2/scans/output_data/module_0/chip_0/20230703_231744_local_threshold_tuning.h5
#CHIP_CONFIG_FILE = /media/bellevtx01/TOSHIBA EXT/configs/tuning/W14R12/01_Normal_THR30_noisy/20230621_124059_threshold_scan_interpreted.h5
#NF_THR30 
#CHIP_CONFIG_FILE = /media/bellevtx01/TOSHIBA EXT/configs/tuning/W14R12/03_Normal_THR30/20230704_094135_threshold_scan_interpreted.h5
#CHIP_CONFIG_FILE = /media/bellevtx01/TOSHIBA EXT/configs/tuning/W14R12/04_HV_THR22/20230705_104444_threshold_scan_interpreted.h5
#CHIP_CONFIG_FILE = /media/bellevtx01/TOSHIBA EXT/configs/tuning/W14R12/05_HV_CASC_THR23/20230705_130222_threshold_scan_interpreted.h5
#CHIP_CONFIG_FILE = /media/bellevtx01/TOSHIBA EXT/configs/tuning/W14R12/06_NF_CASC_THR30/20230601_112557_threshold_scan_interpreted.h5

#W02R05
CHIP_CONFIG_FILE = /media/bellevtx01/TOSHIBA EXT/configs/tuning/W02R05/HV_10V_norm_thr23/20230704_220043_threshold_scan_interpreted.h5
#MASKED_PIXELS_FILE = /media/bellevtx01/TOSHIBA EXT/configs/tuning/W02R05/THR30_cascode/masked_pixels.yaml
CHIP_SN = W02R05
CHIP_CMD_CLK = 160.0

#overriding values in "scan_configuration"
#when none given default ones are being used
START_ROW = 0
STOP_ROW = 512
START_COLUMN = 480
STOP_COLUMN = 492
WAIT_FOR_FPGA = 1

CONFIG_ID = 12
ELOG_CATEGORY = Beam   #  Debug, Beam, VoltageScan, Scan
COMMENT_IN_CONF = "HV_10V_norm_thr23"
ELOG_OUTPUT_PATH = "/media/bellevtx01/TOSHIBA EXT/VTX/data_producer_runs"

[Producer.hameg]
HV = 10
BIAS = 1
SERIAL_PORT = /dev/ttyUSB0

[Monitor.monopix2_mon]
ENABLE_PRINT = 0
ENABLE_STD_PRINT = 0
ENABLE_STD_CONVERTER = 1
FORWARD2GUI = 1

[DataCollector.dc_mpx2]
# connection to the monitor
EUDAQ_MN = monopix2_mon
EUDAQ_FW = native
#path to store .raw file to, $3R is replaced by 3 digit run number, $12D -> 12 character date, $X -> .raw
EUDAQ_FW_PATTERN = /media/bellevtx01/TOSHIBA EXT/VTX/data_producer_runs/desy/run$6R_monopix2$X
#fraction of events being sent to the monitor
EUDAQ_DATACOL_SEND_MONITOR_FRACTION = 100

# config-parameters
#disable output of event to bash, is spamming terminal otherwise
DISABLE_PRINT = 1
ELOG V3.1.5-fc6679b