Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in 2023
Not logged in
List
|
Find
|
Login
|
Help
Message ID:
504
Entry time:
Sun Jul 16 12:24:02 2023
Author:
tb-crew
Subject:
cooled unirradiated
Run Number:
1344
DUT:
RD50-MPW3
Wafer:
unknown
HV:
90
Fluence:
unirradiated
Resistivity:
1.9K
Beam Energy:
4.2
Rate Setting:
Low Flux Low
Particle Type:
electron
Data:
Good
t-Start:
16.07.2023 12:19:03
t-Stop:
16.07.2023 12:19:16
Duration_min:
0
automatic log for run 1344
Comment:
smiley
Attachment 1:
peary_config.cfg
1 kB
|
Show
|
Show all
Attachment 2:
matrix_config_base.txt
3 kB
|
Show
|
Show all
Attachment 3:
matrix_config_piggy.txt
267 Bytes
|
Show
|
Show all
Attachment 4:
eudaq_config.cfg
6 kB
|
Show
|
Show all
ELOG V3.1.5-fc6679b