Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
|
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
|
Testbeam at DESY in 2023 |
Not logged in |
 |
|
Message ID: 435
Entry time: Sat Jul 15 10:02:11 2023
|
Author: |
tb-crew |
Subject: |
irradiated |
Run Number: |
1287 |
DUT: |
RD50-MPW3 |
Wafer: |
unknown |
HV: |
91 |
Fluence: |
1e14 |
Resistivity: |
1.9K |
Beam Energy: |
4.2 |
Rate Setting: |
Low Flux Low |
Particle Type: |
electron |
Data: |
Good |
t-Start: |
15.07.2023 09:22:06 |
t-Stop: |
15.07.2023 09:57:28 |
Duration_min: |
35 |
|
|
automatic log for run 1287
Comment:
thr 1.15V, -0.6 deg C -> lil bit of noise |
|
|
|
|