ID Date Author Subjectdown Run Number DUT Fluence Beam Energy Data t-Start t-Stop Duration_min
  300   Thu Apr 25 22:50:02 2024 RD50 Generic Userinit config W3 NIKHEF      

Bias to compare to others -190V

  308   Fri Apr 26 10:52:03 2024 tb-crewbst thr runs W3 NIKHEFunirradiated4.2Unknown   
calibrated TDACs, HV= -190V
  309   Fri Apr 26 11:08:34 2024 tb-crewbst thr runs286W3 NIKHEFunirradiated4.2Unknown26.04.2024 10:55:1926.04.2024 11:08:5313
crap
  310   Fri Apr 26 11:16:27 2024 tb-crewbst thr runs287W3 NIKHEFunirradiated4.2Unknown26.04.2024 11:10:3326.04.2024 11:16:466
automatic log for run 287
Comment:
calibrated TDACs, HV= -190V (efficiency seems to be a bit lower than HEPHY backside)
  311   Fri Apr 26 11:27:37 2024 tb-crewbst thr runs288W3 NIKHEFunirradiated4.2Unknown26.04.2024 11:22:1826.04.2024 11:27:565
automatic log for run 288
Comment:
calibrated TDACs, HV= -190V (efficiency seems to be a bit lower than HEPHY backside)
  312   Fri Apr 26 11:32:17 2024 tb-crewbst thr runs289W3 NIKHEFunirradiated4.2Unknown26.04.2024 11:29:5526.04.2024 11:32:362
automatic log for run 289
Comment:
calibrated TDACs, HV= -190V (efficiency seems to be a bit lower than HEPHY backside)
  20   Mon Apr 22 18:04:35 2024 tb-crewbasic "best" threshold / HV settings7Wxxx topsideunirradiated4.2Unknown22.04.2024 17:11:4722.04.2024 18:04:5153
automatic log for run 7
Comment:
  21   Mon Apr 22 18:30:31 2024 tb-crewbasic "best" threshold / HV settings8Wxxx topsideunirradiated4.2Unknown22.04.2024 18:05:2122.04.2024 18:30:4725
automatic log for run 8
Comment:
  22   Mon Apr 22 19:35:08 2024 tb-crewbasic "best" threshold / HV settings9Wxxx topsideunirradiated4.2Unknown22.04.2024 18:31:0122.04.2024 19:35:2564
automatic log for run 9
Comment:
  23   Mon Apr 22 19:52:25 2024 tb-crewbasic "best" threshold / HV settings10Wxxx topsideunirradiated4.2Unknown22.04.2024 19:49:3222.04.2024 19:52:423
automatic log for run 10
Comment:
  24   Mon Apr 22 20:51:32 2024 tb-crewbasic "best" threshold / HV settings11Wxxx topsideunirradiated4.2Unknown22.04.2024 19:53:3822.04.2024 20:51:4858
automatic log for run 11
Comment:
  25   Mon Apr 22 22:35:22 2024 tb-crewbasic "best" threshold / HV settings12Wxxx topsideunirradiated4.2Unknown22.04.2024 20:52:4122.04.2024 22:35:39102
automatic log for run 12
Comment:
  26   Mon Apr 22 22:36:44 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
Lost correlations after run #4
  27   Mon Apr 22 22:48:19 2024 tb-crewbasic "best" threshold / HV settings13Wxxx topsideunirradiated4.2Unknown22.04.2024 22:45:1322.04.2024 22:48:353
automatic log for run 13
Comment:
  28   Mon Apr 22 22:51:40 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
Correlations back Big grin
We have to ignore all vetos for whaever fucking reason
  29   Mon Apr 22 23:09:19 2024 tb-crewbasic "best" threshold / HV settings14Wxxx topsideunirradiated4.2Unknown22.04.2024 22:49:2122.04.2024 23:09:3520
automatic log for run 14
Comment:
first effciency value of 86% encountered
  30   Tue Apr 23 09:09:26 2024 tb-crewbasic "best" threshold / HV settings15Wxxx topsideunirradiated4.2Unknown22.04.2024 23:09:4923.04.2024 09:09:43599
automatic log for run 15
Comment:
Running over night (not maybe)
  31   Tue Apr 23 09:13:47 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
Good morning
  32   Tue Apr 23 09:20:22 2024 tb-crewbasic "best" threshold / HV settings16Wxxx topsideunirradiated4.2Unknown23.04.2024 09:14:1223.04.2024 09:20:396
automatic log for run 16
Comment:
  33   Tue Apr 23 09:21:43 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   
number of tracks per event is garbage 0.05 tr/ev so far