Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024, Page 3 of 28  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Fluence Beam Energydown Data t-Start t-Stop Duration_min Text Attachments
  43   Tue Apr 23 10:46:14 2024 tb-crewbasic "best" threshold / HV settings26Wxxx topsideunirradiated4.2Unknown23.04.2024 10:09:2123.04.2024 10:46:3137automatic log for run 26
Comment:
NOT ignoring only MPW4
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  44   Tue Apr 23 10:49:32 2024 tb-crewbasic "best" threshold / HV settings27Wxxx topsideunirradiated4.2Unknown23.04.2024 10:47:4423.04.2024 10:49:482automatic log for run 27
Comment:
switched to triggering on scintillators now
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  45   Tue Apr 23 10:54:38 2024 tb-crewbasic "best" threshold / HV settings28Wxxx topsideunirradiated4.2Unknown23.04.2024 10:50:3523.04.2024 10:54:554automatic log for run 28
Comment:
switched to triggering on scintillators now
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  46   Tue Apr 23 11:18:57 2024 tb-crewbasic "best" threshold / HV settings29Wxxx topsideunirradiated4.2Unknown23.04.2024 10:59:1723.04.2024 11:19:1319automatic log for run 29
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  47   Tue Apr 23 12:39:10 2024 tb-crewbasic "best" threshold / HV settings30Wxxx topsideunirradiated4.2Unknown23.04.2024 11:19:2923.04.2024 12:39:2679automatic log for run 30
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  48   Tue Apr 23 13:05:00 2024 tb-crewbasic "best" threshold / HV settings31Wxxx topsideunirradiated4.2Unknown23.04.2024 12:59:2723.04.2024 13:05:175automatic log for run 31
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  49   Tue Apr 23 13:18:30 2024 tb-crewbasic "best" threshold / HV settings32Wxxx topsideunirradiated4.2Unknown23.04.2024 13:06:2123.04.2024 13:18:4612automatic log for run 32
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  50   Tue Apr 23 13:24:11 2024 tb-crewbasic "best" threshold / HV settings33Wxxx topsideunirradiated4.2Unknown23.04.2024 13:21:1823.04.2024 13:24:283automatic log for run 33
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  51   Tue Apr 23 13:36:11 2024 tb-crewbasic "best" threshold / HV settings35Wxxx topsideunirradiated4.2Unknown23.04.2024 13:35:4023.04.2024 13:36:280automatic log for run 35
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  52   Tue Apr 23 13:40:13 2024 tb-crewbasic "best" threshold / HV settings36Wxxx topsideunirradiated4.2Unknown23.04.2024 13:40:1323.04.2024 13:40:300automatic log for run 36
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  53   Tue Apr 23 13:42:09 2024 tb-crewbasic "best" threshold / HV settings37Wxxx topsideunirradiated4.2Unknown23.04.2024 13:42:1523.04.2024 13:42:260automatic log for run 37
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  54   Tue Apr 23 13:43:52 2024 tb-crewbasic "best" threshold / HV settings38Wxxx topsideunirradiated4.2Unknown23.04.2024 13:43:5323.04.2024 13:44:090automatic log for run 38
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  55   Tue Apr 23 13:47:56 2024 tb-crewbasic "best" threshold / HV settings39Wxxx topsideunirradiated4.2Unknown23.04.2024 13:48:0023.04.2024 13:48:130automatic log for run 39
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  56   Tue Apr 23 13:50:17 2024 tb-crewbasic "best" threshold / HV settings40Wxxx topsideunirradiated4.2Unknown23.04.2024 13:50:0723.04.2024 13:50:340automatic log for run 40
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  57   Tue Apr 23 13:53:38 2024 tb-crewbasic "best" threshold / HV settings41Wxxx topsideunirradiated4.2Unknown23.04.2024 13:52:2823.04.2024 13:53:551automatic log for run 41
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  58   Tue Apr 23 14:15:25 2024 tb-crewbasic "best" threshold / HV settings42Wxxx topsideunirradiated4.2Unknown23.04.2024 13:58:5923.04.2024 14:15:4216automatic log for run 42
Comment:
not ignoring anything an triggering on Telepix,
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  59   Tue Apr 23 14:27:46 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   fixed EUDAQ config bugs   
  60   Tue Apr 23 15:38:43 2024 tb-crewbasic "best" threshold / HV settings43Wxxx topsideunirradiated4.2Unknown23.04.2024 14:28:4123.04.2024 15:39:0070automatic log for run 43
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  61   Tue Apr 23 15:42:58 2024 tb-crewbasic "best" threshold / HV settings44Wxxx topsideunirradiated4.2Unknown23.04.2024 15:39:2723.04.2024 15:43:153automatic log for run 44
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  62   Tue Apr 23 15:58:09 2024 tb-crewbasic "best" threshold / HV settings45Wxxx topsideunirradiated4.2Unknown23.04.2024 15:47:5823.04.2024 15:58:2610automatic log for run 45
Comment:
threshold scan
 peary_config.cfgmatrix_mpw4.txtdefault_0.conf 
ELOG V3.1.5-fc6679b