Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024, Page 2 of 28  Not logged in ELOG logo
Entry  Tue Apr 23 22:00:19 2024, tb-crew, basic "best" threshold / HV settings, 58, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 21:54:44, 23.04.2024 22:00:36, 5 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 58
Comment:
small check run
Entry  Fri Apr 26 11:27:37 2024, tb-crew, bst thr runs, 288, W3 NIKHEF, unirradiated, 4.2, Unknown, 26.04.2024 11:22:18, 26.04.2024 11:27:56, 5 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 288
Comment:
calibrated TDACs, HV= -190V (efficiency seems to be a bit lower than HEPHY backside)
Entry  Fri Apr 26 12:01:17 2024, tb-crew, rotation 20deg, 290, W3 NIKHEF, unirradiated, 4.2, Unknown, 26.04.2024 11:56:27, 26.04.2024 12:01:36, 5 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 290
Comment:
test run
Entry  Tue Apr 23 18:20:06 2024, tb-crew, basic "best" threshold / HV settings, 52, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 17:33:30, 23.04.2024 18:20:23, 46 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 52
Comment:
Entry  Tue Apr 23 10:54:38 2024, tb-crew, basic "best" threshold / HV settings, 28, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 10:50:35, 23.04.2024 10:54:55, 4 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 28
Comment:
switched to triggering on scintillators now
Entry  Wed Apr 24 15:25:21 2024, tb-crew, HV scan, 186, Wxxx topside, unirradiated, 4.2, Unknown, 24.04.2024 15:21:15, 24.04.2024 15:25:39, 4 peary_config.cfgmatrix_mpw4.txtdefault_11.conf
automatic log for run 186
Comment:
running HV scan manually (-210V, -50uA)
Entry  Wed Apr 24 15:44:06 2024, tb-crew, HV scan, 191, Wxxx topside, unirradiated, 4.2, Unknown, 24.04.2024 15:39:31, 24.04.2024 15:44:23, 4 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 191
Comment:
back to HV -190V, too noisy
Entry  Fri Apr 26 23:21:13 2024, tb-crew, HV scan (hi range), 333, W3 LIV, unirradiated, 4.2, Unknown, 26.04.2024 23:17:16, 26.04.2024 23:21:33, 4 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 333
Comment:
telepix masking happening
Entry  Sat Apr 27 11:07:27 2024, tb-crew, HV scan (hi range), 337, W8 LIV, unirradiated, 4.2, Unknown, 27.04.2024 10:28:24, 27.04.2024 11:07:47, 39 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 337
Comment:
trimming done now
Entry  Mon Apr 22 17:08:30 2024, tb-crew, 1t tests, 5, Wxxx topside, unirradiated, 4.2, Unknown, 22.04.2024 16:30:23, 22.04.2024 17:08:47, 38 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 5
Comment:
longer alignment run
Entry  Tue Apr 23 10:46:14 2024, tb-crew, basic "best" threshold / HV settings, 26, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 10:09:21, 23.04.2024 10:46:31, 37 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 26
Comment:
NOT ignoring only MPW4
Entry  Mon Apr 22 19:52:25 2024, tb-crew, basic "best" threshold / HV settings, 10, Wxxx topside, unirradiated, 4.2, Unknown, 22.04.2024 19:49:32, 22.04.2024 19:52:42, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 10
Comment:
Entry  Mon Apr 22 22:48:19 2024, tb-crew, basic "best" threshold / HV settings, 13, Wxxx topside, unirradiated, 4.2, Unknown, 22.04.2024 22:45:13, 22.04.2024 22:48:35, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 13
Comment:
Entry  Tue Apr 23 09:43:02 2024, tb-crew, basic "best" threshold / HV settings, 19, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 09:39:37, 23.04.2024 09:43:19, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 19
Comment:
not ignoring DUT2 (adenium)
Entry  Tue Apr 23 09:59:57 2024, tb-crew, basic "best" threshold / HV settings, 22, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 09:57:09, 23.04.2024 10:00:14, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 22
Comment:
Entry  Tue Apr 23 13:24:11 2024, tb-crew, basic "best" threshold / HV settings, 33, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 13:21:18, 23.04.2024 13:24:28, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 33
Comment:
not ignoring anything an triggering on Telepix, Correlations still fine though...
Entry  Tue Apr 23 15:42:58 2024, tb-crew, basic "best" threshold / HV settings, 44, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 15:39:27, 23.04.2024 15:43:15, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 44
Comment:
Entry  Tue Apr 23 18:24:54 2024, tb-crew, basic "best" threshold / HV settings, 53, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 18:21:23, 23.04.2024 18:25:11, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 53
Comment:
ignoring veto again (yes desperate)
Entry  Tue Apr 23 18:33:47 2024, tb-crew, basic "best" threshold / HV settings, 54, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 18:30:08, 23.04.2024 18:34:04, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 54
Comment:
trying to replicate run14
Entry  Tue Apr 23 19:16:46 2024, tb-crew, basic "best" threshold / HV settings, 55, Wxxx topside, unirradiated, 4.2, Unknown, 23.04.2024 19:13:50, 23.04.2024 19:17:03, 3 peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 55
Comment:
reset the system -> 97%
ELOG V3.1.5-fc6679b