Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Testbeam at DESY in 2024, Page 26 of 28  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Fluence Beam Energy Data t-Start t-Stopdown Duration_min Text Attachments
  13   Mon Apr 22 16:29:40 2024 tb-crew1t tests Wxxx topsideunirradiated4.2Unknown   Correlations seen (firsttry :D )   
  16   Mon Apr 22 17:09:04 2024 tb-crew1t tests Wxxx topsideunirradiated4.2Unknown   we've been ignoring vetos so far   
  18   Mon Apr 22 17:12:17 2024 tb-crew1t tests Wxxx topsideunirradiated4.2Unknown   increaed monitor data   
  19   Mon Apr 22 17:34:19 2024 RD50 Generic Userinitial corry conf geometry         wrng z achses -> use later geo  detectors.geo 
  26   Mon Apr 22 22:36:44 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   Lost correlations after run #4   
  28   Mon Apr 22 22:51:40 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   Correlations back :D
We have to ignore all vetos for whaever fucking
reason
  
  31   Tue Apr 23 09:13:47 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   Good morning   
  33   Tue Apr 23 09:21:43 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   number of tracks per event is garbage 0.05
tr/ev so far
  
  59   Tue Apr 23 14:27:46 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   fixed EUDAQ config bugs   
  69   Tue Apr 23 17:43:13 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   major efficiency problems   
  71   Tue Apr 23 18:21:05 2024 tb-crewbasic "best" threshold / HV settings Wxxx topsideunirradiated4.2Unknown   ignoring veto again (yes desperate)   
  200   Wed Apr 24 15:27:06 2024 tb-crewHV scan Wxxx topsideunirradiated4.2Unknown   tipped in noise with HV increase   
  213   Wed Apr 24 17:01:47 2024 RD50 Generic User         geo for rotated sample, 20 degrees still
need to be added to the DUT (x -> 200)

full aligned
 detectors_rotated.geofull_aligned_backside_hephy_rotated_run_199.geomask_hephy_backside.txt 
  215   Wed Apr 24 17:34:20 2024 tb-crew"best" settings Wxxx backsideunirradiated4.2Unknown   changed DUT   
  217   Wed Apr 24 17:38:43 2024 tb-crew"best" settings Wxxx backsideunirradiated4.2Unknown   adjusting Telepix mask   
  219   Wed Apr 24 17:41:31 2024 RD50 Generic User         initial corry  geo for  backside
biased hephy

full aligned geo from run 202 with
 detectors_backside_hephy.geofull_aligned_backside_hephy_run_202.geomask_hephy_backside.txt 
  220   Wed Apr 24 17:45:49 2024 RD50 Generic User         Corrected geo file for first DUT (hephy/
topside W3) with fixed z

full aligned from run 57 with mask
 full_aligned_run57_test.geofull_aligned_frontside_hephy_run57.geomask_hephy_topside.txt 
  278   Thu Apr 25 17:23:47 2024 tb-crewHV scan Wxxx backsideunirradiated4.2Unknown   loo HV values since a bit   
  283   Thu Apr 25 17:58:39 2024 tb-crewHV scan Wxxx backsideunirradiated4.2Unknown   do not trust bias values in low HV runs, they
are weird (SMU might have been stuck)
  
  284   Thu Apr 25 18:00:36 2024 tb-crewHV scan Wxxx backsideunirradiated4.2Unknown   HV at -4V manually   
ELOG V3.1.5-fc6679b