Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in 2024, Page 26 of 28
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
Wxxx topside
Wxxx backside
W3 NIKHEF
W3 LIV
W8 LIV
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
556 Entries
Goto page
Previous
1
,
2
,
3
...
25
, 26,
27
,
28
Next
ID
Date
Author
Subject
Run Number
DUT
Fluence
Beam Energy
Data
t-Start
t-Stop
Duration_min
Text
13
Mon Apr 22 16:29:40 2024
tb-crew
1t tests
Wxxx topside
unirradiated
4.2
Unknown
Correlations seen (firsttry :D )
16
Mon Apr 22 17:09:04 2024
tb-crew
1t tests
Wxxx topside
unirradiated
4.2
Unknown
we've been ignoring vetos so far
18
Mon Apr 22 17:12:17 2024
tb-crew
1t tests
Wxxx topside
unirradiated
4.2
Unknown
increaed monitor data
19
Mon Apr 22 17:34:19 2024
RD50 Generic User
initial corry conf geometry
wrng z achses -> use later geo
26
Mon Apr 22 22:36:44 2024
tb-crew
basic "best" threshold / HV settings
Wxxx topside
unirradiated
4.2
Unknown
Lost correlations after run #4
28
Mon Apr 22 22:51:40 2024
tb-crew
basic "best" threshold / HV settings
Wxxx topside
unirradiated
4.2
Unknown
Correlations back :D
We have to ignore all vetos for whaever fucking
reason
31
Tue Apr 23 09:13:47 2024
tb-crew
basic "best" threshold / HV settings
Wxxx topside
unirradiated
4.2
Unknown
Good morning
33
Tue Apr 23 09:21:43 2024
tb-crew
basic "best" threshold / HV settings
Wxxx topside
unirradiated
4.2
Unknown
number of tracks per event is garbage 0.05
tr/ev so far
59
Tue Apr 23 14:27:46 2024
tb-crew
basic "best" threshold / HV settings
Wxxx topside
unirradiated
4.2
Unknown
fixed EUDAQ config bugs
69
Tue Apr 23 17:43:13 2024
tb-crew
basic "best" threshold / HV settings
Wxxx topside
unirradiated
4.2
Unknown
major efficiency problems
71
Tue Apr 23 18:21:05 2024
tb-crew
basic "best" threshold / HV settings
Wxxx topside
unirradiated
4.2
Unknown
ignoring veto again (yes desperate)
200
Wed Apr 24 15:27:06 2024
tb-crew
HV scan
Wxxx topside
unirradiated
4.2
Unknown
tipped in noise with HV increase
213
Wed Apr 24 17:01:47 2024
RD50 Generic User
geo for rotated sample, 20 degrees still
need to be added to the DUT (x -> 200)
full aligned
215
Wed Apr 24 17:34:20 2024
tb-crew
"best" settings
Wxxx backside
unirradiated
4.2
Unknown
changed DUT
217
Wed Apr 24 17:38:43 2024
tb-crew
"best" settings
Wxxx backside
unirradiated
4.2
Unknown
adjusting Telepix mask
219
Wed Apr 24 17:41:31 2024
RD50 Generic User
initial corry geo for backside
biased hephy
full aligned geo from run 202 with
220
Wed Apr 24 17:45:49 2024
RD50 Generic User
Corrected geo file for first DUT (hephy/
topside W3) with fixed z
full aligned from run 57 with mask
278
Thu Apr 25 17:23:47 2024
tb-crew
HV scan
Wxxx backside
unirradiated
4.2
Unknown
loo HV values since a bit
283
Thu Apr 25 17:58:39 2024
tb-crew
HV scan
Wxxx backside
unirradiated
4.2
Unknown
do not trust bias values in low HV runs, they
are weird (SMU might have been stuck)
284
Thu Apr 25 18:00:36 2024
tb-crew
HV scan
Wxxx backside
unirradiated
4.2
Unknown
HV at -4V manually