ID |
Date |
Author |
Subject |
Run Number |
DUT |
Fluence |
Beam Energy |
Data |
t-Start |
t-Stop |
Duration_min |
13
|
Mon Apr 22 16:29:40 2024 |
tb-crew | 1t tests | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
Correlations seen (firsttry ) |
16
|
Mon Apr 22 17:09:04 2024 |
tb-crew | 1t tests | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
we've been ignoring vetos so far |
18
|
Mon Apr 22 17:12:17 2024 |
tb-crew | 1t tests | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
increaed monitor data |
19
|
Mon Apr 22 17:34:19 2024 |
RD50 Generic User | initial corry conf geometry | | | | | | | | |
wrng z achses -> use later geo |
26
|
Mon Apr 22 22:36:44 2024 |
tb-crew | basic "best" threshold / HV settings | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
Lost correlations after run #4 |
28
|
Mon Apr 22 22:51:40 2024 |
tb-crew | basic "best" threshold / HV settings | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
Correlations back 
We have to ignore all vetos for whaever fucking reason |
31
|
Tue Apr 23 09:13:47 2024 |
tb-crew | basic "best" threshold / HV settings | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
Good morning |
33
|
Tue Apr 23 09:21:43 2024 |
tb-crew | basic "best" threshold / HV settings | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
number of tracks per event is garbage 0.05 tr/ev so far |
59
|
Tue Apr 23 14:27:46 2024 |
tb-crew | basic "best" threshold / HV settings | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
fixed EUDAQ config bugs |
69
|
Tue Apr 23 17:43:13 2024 |
tb-crew | basic "best" threshold / HV settings | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
major efficiency problems |
71
|
Tue Apr 23 18:21:05 2024 |
tb-crew | basic "best" threshold / HV settings | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
ignoring veto again (yes desperate) |
200
|
Wed Apr 24 15:27:06 2024 |
tb-crew | HV scan | | Wxxx topside | unirradiated | 4.2 | Unknown | | | |
tipped in noise with HV increase |
213
|
Wed Apr 24 17:01:47 2024 |
RD50 Generic User | | | | | | | | | |
geo for rotated sample, 20 degrees still need to be added to the DUT (x -> 200)
full aligned
mask |
215
|
Wed Apr 24 17:34:20 2024 |
tb-crew | "best" settings | | Wxxx backside | unirradiated | 4.2 | Unknown | | | |
changed DUT |
217
|
Wed Apr 24 17:38:43 2024 |
tb-crew | "best" settings | | Wxxx backside | unirradiated | 4.2 | Unknown | | | |
adjusting Telepix mask |
219
|
Wed Apr 24 17:41:31 2024 |
RD50 Generic User | | | | | | | | | |
initial corry geo for backside biased hephy
full aligned geo from run 202 with mask |
220
|
Wed Apr 24 17:45:49 2024 |
RD50 Generic User | | | | | | | | | |
Corrected geo file for first DUT (hephy/ topside W3) with fixed z
full aligned from run 57 with mask |
278
|
Thu Apr 25 17:23:47 2024 |
tb-crew | HV scan | | Wxxx backside | unirradiated | 4.2 | Unknown | | | |
loo HV values since a bit |
283
|
Thu Apr 25 17:58:39 2024 |
tb-crew | HV scan | | Wxxx backside | unirradiated | 4.2 | Unknown | | | |
do not trust bias values in low HV runs, they are weird (SMU might have been stuck) |
284
|
Thu Apr 25 18:00:36 2024 |
tb-crew | HV scan | | Wxxx backside | unirradiated | 4.2 | Unknown | | | |
HV at -4V manually |