Testbeam at DESY in 2024, Page 24 of 28
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
Wxxx topside
Wxxx backside
W3 NIKHEF
W3 LIV
W8 LIV
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
556 Entries
Goto page
Previous
1
,
2
,
3
...
23
, 24,
25
,
26
,
27
,
28
Next
ID
Date
Author
Subject
Run Number
DUT
Fluence
Beam Energy
Data
t-Start
t-Stop
Duration_min
Text
48
Tue Apr 23 13:05:00 2024
tb-crew
basic "best" threshold / HV settings
31
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 12:59:27
23.04.2024 13:05:17
5
automatic log for run 31
Comment:
not ignoring anything an triggering on Telepix,
47
Tue Apr 23 12:39:10 2024
tb-crew
basic "best" threshold / HV settings
30
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 11:19:29
23.04.2024 12:39:26
79
automatic log for run 30
Comment:
not ignoring anything an triggering on Telepix,
46
Tue Apr 23 11:18:57 2024
tb-crew
basic "best" threshold / HV settings
29
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 10:59:17
23.04.2024 11:19:13
19
automatic log for run 29
Comment:
not ignoring anything an triggering on Telepix,
45
Tue Apr 23 10:54:38 2024
tb-crew
basic "best" threshold / HV settings
28
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 10:50:35
23.04.2024 10:54:55
4
automatic log for run 28
Comment:
switched to triggering on scintillators now
44
Tue Apr 23 10:49:32 2024
tb-crew
basic "best" threshold / HV settings
27
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 10:47:44
23.04.2024 10:49:48
2
automatic log for run 27
Comment:
switched to triggering on scintillators now
43
Tue Apr 23 10:46:14 2024
tb-crew
basic "best" threshold / HV settings
26
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 10:09:21
23.04.2024 10:46:31
37
automatic log for run 26
Comment:
NOT ignoring only MPW4
42
Tue Apr 23 10:08:11 2024
tb-crew
basic "best" threshold / HV settings
25
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 10:07:28
23.04.2024 10:08:28
0
automatic log for run 25
Comment:
NOT ignoring only MPW4
41
Tue Apr 23 10:06:18 2024
tb-crew
basic "best" threshold / HV settings
24
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 10:04:47
23.04.2024 10:06:34
1
automatic log for run 24
Comment:
ignoring only MPW4
40
Tue Apr 23 10:03:25 2024
tb-crew
basic "best" threshold / HV settings
23
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 10:01:31
23.04.2024 10:03:42
2
automatic log for run 23
Comment:
ignoring only MPW4
39
Tue Apr 23 09:59:57 2024
tb-crew
basic "best" threshold / HV settings
22
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 09:57:09
23.04.2024 10:00:14
3
automatic log for run 22
Comment:
38
Tue Apr 23 09:54:01 2024
tb-crew
basic "best" threshold / HV settings
21
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 09:52:29
23.04.2024 09:54:18
1
automatic log for run 21
Comment:
ignore everything again
37
Tue Apr 23 09:50:07 2024
tb-crew
basic "best" threshold / HV settings
20
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 09:48:27
23.04.2024 09:50:24
1
automatic log for run 20
Comment:
not ignoring anything
36
Tue Apr 23 09:43:02 2024
tb-crew
basic "best" threshold / HV settings
19
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 09:39:37
23.04.2024 09:43:19
3
automatic log for run 19
Comment:
not ignoring DUT2 (adenium)
35
Tue Apr 23 09:36:59 2024
tb-crew
basic "best" threshold / HV settings
18
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 09:30:46
23.04.2024 09:37:16
6
automatic log for run 18
Comment:
not ignoring DUT0 (telepix) and DUT2 (Adenium)
34
Tue Apr 23 09:28:35 2024
tb-crew
basic "best" threshold / HV settings
17
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 09:23:05
23.04.2024 09:28:52
5
automatic log for run 17
Comment:
not ignoring DUT0 (telepix)
32
Tue Apr 23 09:20:22 2024
tb-crew
basic "best" threshold / HV settings
16
Wxxx topside
unirradiated
4.2
Unknown
23.04.2024 09:14:12
23.04.2024 09:20:39
6
automatic log for run 16
Comment:
30
Tue Apr 23 09:09:26 2024
tb-crew
basic "best" threshold / HV settings
15
Wxxx topside
unirradiated
4.2
Unknown
22.04.2024 23:09:49
23.04.2024 09:09:43
599
automatic log for run 15
Comment:
Running over night (not maybe)
29
Mon Apr 22 23:09:19 2024
tb-crew
basic "best" threshold / HV settings
14
Wxxx topside
unirradiated
4.2
Unknown
22.04.2024 22:49:21
22.04.2024 23:09:35
20
automatic log for run 14
Comment:
first effciency value of 86% encountered
27
Mon Apr 22 22:48:19 2024
tb-crew
basic "best" threshold / HV settings
13
Wxxx topside
unirradiated
4.2
Unknown
22.04.2024 22:45:13
22.04.2024 22:48:35
3
automatic log for run 13
Comment:
25
Mon Apr 22 22:35:22 2024
tb-crew
basic "best" threshold / HV settings
12
Wxxx topside
unirradiated
4.2
Unknown
22.04.2024 20:52:41
22.04.2024 22:35:39
102
automatic log for run 12
Comment:
Goto page
Previous
1
,
2
,
3
...
23
, 24,
25
,
26
,
27
,
28
Next
ELOG V3.1.5-fc6679b