Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Testbeam at DESY in 2024, Page 22 of 28
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
Wxxx topside
Wxxx backside
W3 NIKHEF
W3 LIV
W8 LIV
-- Beam Energy --
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
5.2
5.4
5.6
5.8
6.0
556 Entries
Goto page
Previous
1
,
2
,
3
...
21
, 22,
23
...
26
,
27
,
28
Next
ID
Date
Author
Subject
Run Number
DUT
Fluence
Beam Energy
Data
t-Start
t-Stop
Duration_min
Text
366
Fri Apr 26 23:11:50 2024
tb-crew
HV scan (hi range)
W3 NIKHEF
unirradiated
4.2
Unknown
test
367
Fri Apr 26 23:12:23 2024
tb-crew
HV scan (hi range)
W3 LIV
unirradiated
4.2
Unknown
test
368
Fri Apr 26 23:14:32 2024
tb-crew
HV scan (hi range)
332
W3 LIV
unirradiated
4.2
Unknown
26.04.2024 23:13:38
26.04.2024 23:14:52
1
automatic log for run 332
Comment:
test
369
Fri Apr 26 23:15:00 2024
tb-crew
HV scan (hi range)
W3 LIV
unirradiated
4.2
Unknown
telepix masking happening
370
Fri Apr 26 23:15:22 2024
tb-crew
HV scan (hi range)
W3 LIV
unirradiated
4.2
Unknown
telepix masking happening
371
Fri Apr 26 23:21:13 2024
tb-crew
HV scan (hi range)
333
W3 LIV
unirradiated
4.2
Unknown
26.04.2024 23:17:16
26.04.2024 23:21:33
4
automatic log for run 333
Comment:
telepix masking happening
372
Fri Apr 26 23:21:36 2024
tb-crew
HV scan (hi range)
W3 LIV
unirradiated
4.2
Unknown
DUT sems to have "problems"
373
Fri Apr 26 23:29:21 2024
tb-crew
HV scan (hi range)
W8 LIV
unirradiated
4.2
Unknown
changed DUT
374
Fri Apr 26 23:32:05 2024
tb-crew
HV scan (hi range)
334
W8 LIV
unirradiated
4.2
Unknown
26.04.2024 23:32:19
26.04.2024 23:32:25
0
automatic log for run 334
Comment:
changed DUT
375
Fri Apr 26 23:39:38 2024
tb-crew
HV scan (hi range)
W8 LIV
unirradiated
4.2
Unknown
HV = -190V
376
Sat Apr 27 09:29:54 2024
tb-crew
HV scan (hi range)
335
W8 LIV
unirradiated
4.2
Unknown
26.04.2024 23:40:34
27.04.2024 09:30:14
589
automatic log for run 335
Comment:
HV = -190V, overnight
377
Sat Apr 27 09:39:53 2024
tb-crew
HV scan (hi range)
336
W8 LIV
unirradiated
4.2
Unknown
27.04.2024 09:40:10
27.04.2024 09:40:13
0
automatic log for run 336
Comment:
379
Sat Apr 27 10:27:04 2024
tb-crew
HV scan (hi range)
W8 LIV
unirradiated
4.2
Unknown
trimming done now
380
Sat Apr 27 11:07:27 2024
tb-crew
HV scan (hi range)
337
W8 LIV
unirradiated
4.2
Unknown
27.04.2024 10:28:24
27.04.2024 11:07:47
39
automatic log for run 337
Comment:
trimming done now
512
Sun Apr 28 09:52:48 2024
tb-crew
HV scan (hi range)
467
W3 NIKHEF
unirradiated
4.2
Unknown
28.04.2024 09:52:58
28.04.2024 09:53:09
0
automatic log for run 467
Comment:
513
Sun Apr 28 10:03:41 2024
tb-crew
HV scan (hi range)
468
W3 NIKHEF
unirradiated
4.2
Unknown
28.04.2024 09:53:59
28.04.2024 10:04:02
10
automatic log for run 468
Comment:
514
Sun Apr 28 10:14:21 2024
tb-crew
HV scan (hi range)
469
W3 NIKHEF
unirradiated
4.2
Unknown
28.04.2024 10:04:39
28.04.2024 10:14:42
10
automatic log for run 469
Comment:
515
Sun Apr 28 10:25:00 2024
tb-crew
HV scan (hi range)
470
W3 NIKHEF
unirradiated
4.2
Unknown
28.04.2024 10:15:17
28.04.2024 10:25:21
10
automatic log for run 470
Comment:
516
Sun Apr 28 10:35:39 2024
tb-crew
HV scan (hi range)
471
W3 NIKHEF
unirradiated
4.2
Unknown
28.04.2024 10:25:56
28.04.2024 10:36:00
10
automatic log for run 471
Comment:
517
Sun Apr 28 10:46:18 2024
tb-crew
HV scan (hi range)
472
W3 NIKHEF
unirradiated
4.2
Unknown
28.04.2024 10:36:35
28.04.2024 10:46:39
10
automatic log for run 472
Comment:
Goto page
Previous
1
,
2
,
3
...
21
, 22,
23
...
26
,
27
,
28
Next