IDdown Date Author Subject Run Number DUT Fluence Beam Energy Data t-Start t-Stop Duration_min Text Attachments
  216   Wed Apr 24 17:37:23 2024 tb-crew"best" settings200Wxxx backsideunirradiated4.2Unknown24.04.2024 17:36:3324.04.2024 17:37:411automatic log for run 200
Comment:
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  215   Wed Apr 24 17:34:20 2024 tb-crew"best" settings Wxxx backsideunirradiated4.2Unknown   changed DUT   
  214   Wed Apr 24 17:11:45 2024 tb-crewHV scan199Wxxx topsideunirradiated4.2Unknown24.04.2024 16:51:4424.04.2024 17:12:0220automatic log for run 199
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  213   Wed Apr 24 17:01:47 2024 RD50 Generic User         geo for rotated sample, 20 degrees still
need to be added to the DUT (x -> 200)

full aligned
 detectors_rotated.geofull_aligned_backside_hephy_rotated_run_199.geomask_hephy_backside.txt 
  212   Wed Apr 24 16:49:01 2024 tb-crewHV scan198Wxxx topsideunirradiated4.2Unknown24.04.2024 16:48:4024.04.2024 16:49:180automatic log for run 198
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  211   Wed Apr 24 16:47:43 2024 tb-crewHV scan197Wxxx topsideunirradiated4.2Unknown24.04.2024 16:47:0724.04.2024 16:48:010automatic log for run 197
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  210   Wed Apr 24 16:45:41 2024 tb-crewHV scan196Wxxx topsideunirradiated4.2Unknown24.04.2024 16:45:3924.04.2024 16:45:590automatic log for run 196
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  209   Wed Apr 24 16:43:41 2024 tb-crewHV scan195Wxxx topsideunirradiated4.2Unknown24.04.2024 16:42:5324.04.2024 16:43:591automatic log for run 195
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  208   Wed Apr 24 16:41:20 2024 tb-crewHV scan194Wxxx topsideunirradiated4.2Unknown24.04.2024 16:38:4324.04.2024 16:41:382automatic log for run 194
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  207   Wed Apr 24 16:37:39 2024 tb-crewHV scan193Wxxx topsideunirradiated4.2Unknown24.04.2024 16:35:2224.04.2024 16:37:572automatic log for run 193
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  206   Wed Apr 24 16:26:17 2024 tb-crewHV scan192Wxxx topsideunirradiated4.2Unknown24.04.2024 16:17:0724.04.2024 16:26:349automatic log for run 192
Comment:
rotated DUT by ~20deg
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  205   Wed Apr 24 15:44:06 2024 tb-crewHV scan191Wxxx topsideunirradiated4.2Unknown24.04.2024 15:39:3124.04.2024 15:44:234automatic log for run 191
Comment:
back to HV -190V, too noisy
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  204   Wed Apr 24 15:35:03 2024 tb-crewHV scan190Wxxx topsideunirradiated4.2Unknown24.04.2024 15:35:1124.04.2024 15:35:210automatic log for run 190
Comment:
changing thr now
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  203   Wed Apr 24 15:33:22 2024 tb-crewHV scan189Wxxx topsideunirradiated4.2Unknown24.04.2024 15:33:1124.04.2024 15:33:390automatic log for run 189
Comment:
changing thr now
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  202   Wed Apr 24 15:32:05 2024 tb-crewHV scan188Wxxx topsideunirradiated4.2Unknown24.04.2024 15:31:4724.04.2024 15:32:220automatic log for run 188
Comment:
changing thr now
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  201   Wed Apr 24 15:29:38 2024 tb-crewHV scan187Wxxx topsideunirradiated4.2Unknown24.04.2024 15:27:5824.04.2024 15:29:561automatic log for run 187
Comment:
tipped in noise with HV increase
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  200   Wed Apr 24 15:27:06 2024 tb-crewHV scan Wxxx topsideunirradiated4.2Unknown   tipped in noise with HV increase   
  199   Wed Apr 24 15:25:21 2024 tb-crewHV scan186Wxxx topsideunirradiated4.2Unknown24.04.2024 15:21:1524.04.2024 15:25:394automatic log for run 186
Comment:
running HV scan manually (-210V, -50uA)
 peary_config.cfgmatrix_mpw4.txtdefault_11.conf 
  198   Wed Apr 24 14:53:39 2024 tb-crewHV scan185Wxxx topsideunirradiated4.2Unknown24.04.2024 14:33:5424.04.2024 14:53:5720automatic log for run 185
Comment:
running HV scan
 peary_config.cfgmatrix_mpw4.txtdefault_11.conf 
  197   Wed Apr 24 14:33:01 2024 tb-crewHV scan184Wxxx topsideunirradiated4.2Unknown24.04.2024 14:13:1524.04.2024 14:33:1920automatic log for run 184
Comment:
running HV scan
 peary_config.cfgmatrix_mpw4.txtdefault_10.conf 
ELOG V3.1.5-fc6679b